-2- USE INSTRUCTIONS TFS 100
28/38
7.1.3 CLEANING
PROCEDURES
At the commencement of cleaning the machine, for the good of the user, make
sure that the main switch is in the “0” position if by chance you have the metallic safety
guards turned on, or the safety devices activated as without these, dangerous
situations may arise for the operator.
The user should utilise gloves, safety glasses, etc., when using cleaning
substances and be careful with alcohol-based disinfectants as they may cause burning
of the skin. The user should also bear in mind the safety instructions and the operating
instructions of the above-mentioned products.
As has been stated previously, before commencing to clean the machine, make
sure the main switch is in the “0” position. After checking this, you can wash the
machine without take off the covers with hot water. Then you must take off the covers
and you can remove the biggest part of dirty with air pressure ( until 3 or 4 bar ) after
that you can wash the machine using a wet cloth with mild detergent .Next dry the
machine using air jet again.
If you proceed to disinfecting the machine, spray the entire machine with an
alcohol-based disinfectant once you have finished cleaning the machine. When
sufficient time has passed for the desinfection of the machine, the machine is rinsed
using enough hot water.
IMPORTANT NOTE:
Bearing in mind that the disinfectants degrease the metal,
you should return to cover the film of grease on the metal with an antioxidant product
such as white oil to protect against corrosion. Before applying the antioxidant, you
should polish any possible corrosion areas.
It is recomended to double check the pipes of the machine periodically,
and to proceed cleaning where ever is obstructed.
Suppliers of Detergents
To make any queries regarding the suppliers, we suggest that you contact
ULMA Packaging or speak directly to your representative.
7.2 MECHANICAL MAINTENANCE
-DAILY:
-Clean conveyor (open grips and inlet roller)
-Clean transport guides.
-Check air and water pressure. Adjust if necessary.
-Check maintenance unit (filter group).
-Check heating plates. We recommend to eliminate dirt and plastic materials
when still hot.
-Check oil level in the pump. First oil change must be done after 100 hours’ work
(alimentary synthetic oil and SAE 30 viscosity). Oil change not necessary in oxygen
pump.
-Deposit purge
Содержание TFS100
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 16: ......
Страница 18: ...2 USE INSTRUCTIONS TFS 100 2 38 8 1 FILM COIL STORAGE AND TRANSPORT 37 8 2 INSERTION OF PRODUCTS IN TRAYS 38...
Страница 26: ...2 USE INSTRUCTIONS TFS 100 10 38...
Страница 28: ...2 USE INSTRUCTIONS TFS 100 12 38 3 8 ELECTRONIC CABINET...
Страница 40: ...2 USE INSTRUCTIONS TFS 100 24 38...
Страница 48: ...2 USE INSTRUCTIONS TFS 100 32 38 GREASERS 9372726 GREASE CUP Lubrication points...
Страница 56: ......
Страница 58: ...3 SCREEN PP45 2 29...
Страница 82: ...3 SCREEN PP45 26 29...