- 16 -
≪2.Content of the each mode and set value≫
Mode No.
Measuring types, Measurement unit, Display decimal point
0
A B C D E
0.0 0 2 1
Display decimal point setting
0: 0 2: 0.00
1: 0.0 3:0.000
Measuring unit
0:hour
1:minute
2:second
3:hour-minute The above measurement selecting
4:minute-second 08,13 - 15 alone can be used.
Measuring types
00:A-input:speed, rotation, flow rate measurement
01:B-input:speed, rotation, flow rate measurement
02:Ratio measurement (absolute ratio measurement)
B/A×100
03:Ratio measurement (error ratio measurement)
(B-A)/A×100
04:Ratio measurement (difference measurement)
A-B
05:Ratio measurement (density)
B/(A+B)×100
06:Ratio measurement (sum measurement)
A+B
07:Ratio measurement (differential rate measurement)
(A+B)/R or (A-B)/R
08:Passing time measurement
09:Shot speed UA (2 sensor one direction speed)
10:Shot speed UB1 (1 senor one direction speed)
11:Shot speed UB2 (1 sensor reciprocal speed)
12:Shot speed UC (2 sensor reciprocal speed)
13:Cycle-timer measurement
14:Stop watch A
15:Stop watch B
NOTE:Upon setting 16 - 19, same operation as with 00 is mode.
Option:AV3-5/AI
In analog output,
The real-time output functions only when I set Mode No.0
“
00
”
(A input) or
“
01
”
(B input) or
“
08
”
(Passing time measurement).
Otherwise, set it in 1(Synchronizes for the display).
When use analog output, the measurement unit choose 0(hour) or
1(minute) or 2(second).
(00)
(01)
〔Ratemeter〕
When I use it in Ratemeter (speed, rotation,flow rate), choose this mode.
Choose
“
00
”
(A input) or
“
01
”
(B input).