66
3.1.1.
Gripper Installation
Installation of gripper:
1.
Move the robotic arm to a safe position. Avoid collision with the robotic
arm mounting surface or other equipment;
2.
Power off the robotic arm by pressing the emergency stop button on
the control box;
3.
Fix the gripper on the end of the robotic arm with 2 M6 bolts;
4.
Connect the robotic arm and the gripper with the gripper connection
cable;
Note:
1.
When wiring the gripper connection cable, be sure to power off the
robotic arm, to set the emergency stop button in the pressed state, and