![UCORE ELECTRONICS UCE-DSO4200C Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ucore-electronics/uce-dso4200c/uce-dso4200c_user-manual_3182462008.webp)
https://ucore-electronics.com
7
2.1.
Rotary encoder functions
Rotary-1
Function
Menu
Clockwise
counterclockwise
Button
Booting
-
-
When pressed and held, the device
connects as a USB disk. (If connected to
computer with USB cable)
Main menu
-
-
-
Oscilloscope
CH-1 Volt/div value decreases
CH-1 offset value increases
CH-math gain increases
CH-math offset increases
CH-1 Volt/div value increases
CH-1 offset value decreases
CH-math gain decreases
CH-math offset decreases
Pressing the button once will switch
between
Volt/div
and
offset
.
If the math function is active;
Volt/div
→
offset
→
math gain
→
math
offset
toggle between them.
Curve Tracer
Test voltage value decreases
Test voltage value increases
Increases the scan period if the scan
mode is active
Signal generator
Increases the digit value of the
selected parameter
Decreases the digit value of the
selected parameter
-
Short circuit
-
-
-
File browser
Scrolls down the page if the number
of files exceeds the page.
Scrolls the page up
-
System
Increases first parameter in DDS
OFFSET and DDS GAIN menu
Decreases first parameter in DDS
OFFSET and DDS GAIN menu
-
Rotary-2
Function
Menu
Clockwise
counterclockwise
Button
Booting
-
-
-
Main menu
-
-
-
Oscilloscope
CH-2 Volt/div value decreases
CH-2 offset value increases
CH-2 Volt/div value increases
CH-2 offset value decreases
Pressing the button once will switch
between
Volt/div
and
offset
.
Curve Tracer
Frequency value decreases
Frequency value increases
Decreases scan period if scan mode is
active
Signal generator
Shifts the active digit to the right
Shifts the active digit to the left
-
Short circuit
-
-
-
File browser
Selects the file (or folder) just below
Selects the file (or folder) just
above
Opens the selected file or folder
System
Increases the second parameter in
the DDS OFFSET and DDS GAIN
menu
Decreases second parameter in
DDS OFFSET and DDS GAIN menu
-
Rotary-3
Function
Menu
Clockwise
counterclockwise
Button
Booting
-
-
When pressed and held, the device
connects as a USB disk. (If connected to
computer with USB cable)
Main menu
-
-
-
Oscilloscope
Time/div value decreases
Trigger level value increases
Shifts the buffer forward in STOP
mode
Time /div value increases
Trigger level value decreases
Shifts the buffer back in STOP mode
Pressing the button once toggles
between
Time/div
and
trigger level
.
If triggering is stopped, toggle between
Time/div
and
buffer scrolling
Curve Tracer
Limit resistor value decreases
Limit resistor value increases
-
Signal generator
The above parameter is selected
The below parameter is selected
-
Short circuit
-
-
-
File browser
-
-
-
System
Increases LCD backlight