62 Troubleshooting
Dimension BST 1200es / SST 1200 es User Guide
Cannot communicate with system
through network (Continued)
Re-configure settings per (see
).
If using a Static network address, verify that the
IP address entered in CatalystEX has the same
value as the address entered for the printer.
Your system configuration may have changed.
Contact your Network Administator.
Error Code displayed on Display
Panel
Call your local reseller for customer service. For
more information, refer to
Determination Codes” on page 63.
.
Display Panel displays
Build Error
Partial or bad part file sent to system. Check STL
file validity in CAD software; reprocess STL in
Catalyst and redownload to system.
Display Panel displays
Can’t Find Home –
Check Modeling
Base
Verify a modeling base is inserted.
Modeling base may be used or defective –
replace.
Display Panel displays
Communication lost
at HR:MN UCT
The system stopped reporting its status at the
Universal Coordinated Time (UCT) shown. Wait
for the system to complete building the part. The
system will automatically restart and display Build
Complete. It is then safe to remove the model.
Display Panel displays
Could Not Read
Cartridge
Remove cartridge and cycle power (see
); reload
cartridge.
Try a different cartridge.
Display Panel displays
Load Failed
Retry with same cartridge.
Try a different cartridge.
Filament may be jammed in extrusion head (see
“Loss of Extrusion” on page 63.
Problem or error message
Solution
Содержание BST 1200es
Страница 1: ...BST 1200es SST 1200es User Guide...
Страница 6: ...6 DimensionBST1200es SST1200esUserGuide...
Страница 10: ...10 DimensionBST1200es SST1200esUserGuide...
Страница 72: ...72 Troubleshooting DimensionBST1200es SST1200esUserGuide...
Страница 73: ...Dimension BST 1200es SST 1200es User Guide Troubleshooting 73...