9. After approximately 5 seconds, reduce pressure against the
toggle spring and allow the idler wheel to contact the filament.
Filament should extrude from the clogged tip.
NOTE
The blower will automatically turn on in 10 seconds.
10. Press
Stop
on the interface panel.
11. Move the toggle bar to activate the drive wheel control options
for the non-clogged side.
12. Press
Forward
on the interface panel. Make sure that filament
extrudes from the non-clogged liquefier.
NOTE
It is necessary to confirm proper operation of the non-
clogged side. Temporarily having the blower off can
occasionally cause the non-clogged side to clog.
13. Press
Stop
on the interface panel.
14. Install plastic head cover.
15. Exit
Maintenance
- press
Next
> then
Done
.