Troubleshooting 63
Fault Determination Codes
If a fault occurs, which would prevent Dimension from executing an
operator request, the system will begin to shut down and cool. The
panel will display one or two error codes. An error-code list (with
the filename “error.txt”) can be found on the CD-ROM for the
controller software. (
Because this list may change with each new
software version, be sure to check the error.txt attachment when
you download new software upgrades.)
After the printer has finished cooling, the only option displayed is
Continue
. Press
Continue
and the printer reboots and tries to
return to normal operation. If pressing
Continue
does not recover
the printer, the printer should be power cycled (see
); wait 60 seconds before switching power on again. In
most cases you will be able to continue operation. However, if the
printer continues to shut down and display the same error, call your
service representative.
Loss of Extrusion
Diagnosing Loss of Extrusion
Occasionally, the printer’s head may experience loss of extrusion.
This will be evident by observing one of the following:
•
Seeing the head moving with no material coming out of
either liquefier tip
•
The height of the model and support materials are not
equal
•
Sagging structures due to lack of support materials
Diagnose loss of extrusion:
1. Press
Cancel
and remove any parts from the printer.
WARNING
The head area is very hot!! Use gloves
when working in this area of printer!
Содержание BST 1200es
Страница 1: ...BST 1200es SST 1200es User Guide...
Страница 6: ...6 DimensionBST1200es SST1200esUserGuide...
Страница 10: ...10 DimensionBST1200es SST1200esUserGuide...
Страница 72: ...72 Troubleshooting DimensionBST1200es SST1200esUserGuide...
Страница 73: ...Dimension BST 1200es SST 1200es User Guide Troubleshooting 73...