70 Troubleshooting
Dimension BST 1200es / SST 1200 es User Guide
1. Enter
Maintenance
mode.
From
Idle
, press
Maintenance > Machine
> then
Head
.
2. Move the material idler wheel out of the way on the side that is
clogged. Use a 7/64 and 1/8 T-Handle as illustrated in
(model side shown).
3. Move the toggle bar so as to ‘deactivate’ the clogged tip.
NOTE
Push the toggle bar to the right to deactivate the support
side; push the toggle bar to the left to deactivate the
model side.
4. Snip the filament just after the it passes between the filament
drive and the idler wheel (‘pinch point’).
NOTE
If necessary manually pull more filament forward in
order to reach the ‘pinch point’.
5. Move the toggle bar to activate the clogged side. This will
make the drive wheel control options active for the clogged
side.
NOTE
Push the toggle bar to the left to activate the support
side; push the toggle bar to the right to activate the
model side.
6. Press
Forward
on the interface panel. The drive wheel will
turn, but filament will not feed because the idler wheel is held
out of position.
7. Use the 7/64 T-Handle to hold pressure against the toggle
spring and keep the idler wheel away from the filament.
Remove the 1/8 T-Handle.
8. Press
Blower Off
on the interface panel. With the head
blower off the temperature the liquefier tube will increase.
Содержание BST 1200es
Страница 1: ...BST 1200es SST 1200es User Guide...
Страница 6: ...6 DimensionBST1200es SST1200esUserGuide...
Страница 10: ...10 DimensionBST1200es SST1200esUserGuide...
Страница 72: ...72 Troubleshooting DimensionBST1200es SST1200esUserGuide...
Страница 73: ...Dimension BST 1200es SST 1200es User Guide Troubleshooting 73...