Operation
40
Document Number 206465-0001
User Guide
The display panel during build
The top two lines of the display panel will show the printer status. See
Figure 32
. The bottom line of the
display panel will show the amount of model and support material that remains in the carriers.
Figure 32: Display panel during build
Note:
If a material amount is flashing, it indicates that the
remaining material will not be enough to complete the
current build.
Chamber Lights
When a part starts to build, the chamber lights are automatically ON. The default time-out for the lights is
30 minutes. You can toggle the lights ON or OFF through the display panel.
You can set the chamber lights on permanently, however the chamber lights will return to factory settings
when power is cycled.
1. From
Idle
or
Ready to Build
, on the display panel press
Maintenance
.
2.
Press
Setup
.
3.
Press
Lights Always On
.
Repeat this process to turn this option off.
Printer status
Model file name
Support material
remaining
Model material
remaining
Printer status
Model file name
Support material
remaining in bay 1
Support material
remaining in bay 2
Model material remaining
in bay1
Model material remaining
in bay2
Single material bay