Problems
Causes
Countermeasures
Inoperative
horn
Burnt out fuse
Inspect and renew.Check circuit before re-
connecting power
Loose or broken wires of
connections
Inspect circuit,tighten connections,or renew
wiring
Defective horn switch
Check and renew
Defective horn
Check and renew
Cruise does
not operate
Burnt out fuse
Inspect and renew.Check circuit before re-
connecting power
Loose or broken wire
Inspect circuit,tighten connections,or renew
wiring
Loose the magnetic assembly
Inspect circuit,tighten connections
3.GLOW SYSTEM
Problems
Causes
Countermeasures
All glow
plugs do not
heat red
Discharged Battery
Check battery and charge or renew
Loose or defective battery cable
connections
Inspect,clean,and tighten connections
10-17
Loose wire harness connections
Check and ensure connectors securely
engaged
Burnt out fuse
Inspect and renew.Check circuit before re-
connecting power
Faulty wiring
Check glow plug circuit wiring and repair
or renew
Defective main switch
Check and renew
Individual
glow plug
does not glow
Defective glow plug
Check and renew
Defective or corroded glow plug
contacts
Inspect,Clean,or renew
Loose or broken wires
Inspect,secure,repair,or renew wiring
Glow monitor
light does not
illuminate
Defective glow timer
Check and renew
Defective glow monitor light or
monitor and warning check unit
See”Light system troubleshooting”
Содержание T233 HST
Страница 14: ...1 11...
Страница 15: ...1 12...
Страница 22: ...SECTION 3 GEAR TRAIN DIAGRAMS FIG 1 3 GEAR TRAIN DIAGRAM 1 19...
Страница 33: ...SECTION 2 OPERATION CHART FOR DISASSEMBLY AND REASSEMBLY BY MAJOR BLOCKS 2 4...
Страница 60: ...3 HST main pump case 4 5...
Страница 64: ...6 Hydrostatic system schematic 4 8...
Страница 100: ...3 Rear transmission case 5 15 Fig 5 23...
Страница 121: ...Power Train Diagram Fig 5 60 5 36...
Страница 210: ...SECTION 6 WIRING DIAGRAM 10 12...