2.FLOW-DIVIDER
GENERAL DESCRIPTION
This valve is installed to bypass working fluid of a specified pressure from the main circuit into the
PTO circuit through a fixed orifice. It includes a changeover valve for engaging and disengage the
PTO clutch by means of a solenoid and a sequential valve for PTO circuit's over the main circuit.
(1) PTO Solenoid valve
(1)Solenoid
This solenoid is switched on or off by operating the PTO switch.
The oil pressure flows from the back
pressure of the power steering valve.
(2)PTO changeover valve
This valve is composed of the spool and spring.When the solenoid is switched on, the spool is moved
to the left by overcoming the spring force and allows the fluid from the drain port of the steering valve.
(1) PTO Solenoid valve
(2) Hydrostatic unit
Fig.9-3