OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
GRANULAR MONITOR MATERIAL TYPE / 63
6011258 Rev C
GRANULAR MONITOR MATERIAL TYPE
Select Granular Monitor setup for fertilizer and crop protect
applications using hydraulic control systems.
Figure 43
Granular Monitor Screen
TYPE
Read-only field that shows Granular Monitor for reference.
PRODUCT CLASS
Product class identifies the type of application as either (fertilizer,
seeding or crop protect i.e., insecticide).
UNITS
The rate units used for the material in pounds per acre (LB/AC),
kilograms per hectare (KG/HA).
PRESET METHOD ENABLED
The Preset Method table allows 10 user-defined target rates to
be entered. When enabled, target rates can be adjusted from the
Work Screen using the Increment/Decrement buttons.
PRESET METHOD DISABLED
When Preset Method is disabled, the target rate on the
Work Screen can be adjusted by pressing the Material
Increment/Decrement buttons. The target rate increases or
decreases based on the Inc/Dec % value set at the Material
Configuration screen.
Содержание DICKEY-john INTELLIAG ISO6
Страница 111: ...OPERATOR S MANUAL 106 SECTION CONTROL ISO6 Version 4 UL 2_3 Manual 6011258 Rev C Figure 71 Assigning Clutch Sections ...
Страница 115: ...OPERATOR S MANUAL 110 SECTION LINKING ISO6 Version 4 UL 2_3 Manual 6011258 Rev C Figure 74 Linking Sections ...
Страница 197: ...OPERATOR S MANUAL 192 VERSION INFORMATION ISO6 Version 4 UL 2_3 Manual 6012487 Rev A ...
Страница 205: ...OPERATOR S MANUAL 200 DIAGNOSTICS ISO6 Version 4 UL 2_3 Manual 6011258 Rev C Figure 154 Manual Open of a Channel ...