OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
COMPONENT INSTALLATION / 17
6011258 Rev C
Figure 14
Incorrect Seed Sensor Module Connection
Failure to correctly install seed sensors will result in incorrect row
assignment on the planter monitor display functions and alarms.
HOPPER LEVEL SENSORS
The system is compatible with the DICKEY-john planter hopper
level sensors. One hopper level sensor can connect to the
actuator harness and another 4 hopper sensors connect using
an accessory harness (P/N 46798-0201). Both harnesses are
connected to the ISO
6
. The hopper level connection is labeled
HOPPER 1 2.
RPM SENSORS
The system is compatible with all existing DICKEY-john digital
RPM sensors. One RPM sensor connects to the ISO
6
module.
The sensor connects to the actuator harness and is labeled
RPM 1. Up to 3 additional RPM sensors connect to an accessory
harness (P/N 46798-0201).