OPERATOR’S MANUAL
54 / GRANULAR SEEDING MATERIAL TYPE
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
Figure 38
Material Setup - Granular Control Page 2
NOTE
Press the Arrow button on the Materials screen to view
second screen.
THOUSAND WEIGHT GRAIN
The weight of 1000 seeds in either ounces or grams. This setting
is used when calculating population values and triggering
alarms. The Thousand Grain Weight is also used when material
Units are set to KS/AC or Seeds/Ft2 to convert the target rate to
LBS/AC or KG/HA. Editing this setting will update the Seeds per
Pound setting.
This number can be found by counting out 1000 seeds and
weighing them, or it may be printed on the seed bag. This setting
is only used for materials with Seeding type for Product Class.
HIGH/LOW POPULATION ALARMS
The High and Low Alarm option sets the high and low population
limit values. The entered value is dependent on the target rate.
This setting is only used for materials with seeding type for
Product Class.
The High and Low Alarms are entered as a percentage. The
percentage value is referenced in relation to the Target Rate x
Seed/Lb setting.
Содержание DICKEY-john INTELLIAG ISO6
Страница 111: ...OPERATOR S MANUAL 106 SECTION CONTROL ISO6 Version 4 UL 2_3 Manual 6011258 Rev C Figure 71 Assigning Clutch Sections ...
Страница 115: ...OPERATOR S MANUAL 110 SECTION LINKING ISO6 Version 4 UL 2_3 Manual 6011258 Rev C Figure 74 Linking Sections ...
Страница 197: ...OPERATOR S MANUAL 192 VERSION INFORMATION ISO6 Version 4 UL 2_3 Manual 6012487 Rev A ...
Страница 205: ...OPERATOR S MANUAL 200 DIAGNOSTICS ISO6 Version 4 UL 2_3 Manual 6011258 Rev C Figure 154 Manual Open of a Channel ...