OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
SECTION CONTROL / 105
6011258 Rev C
Figure 70
Clutch Output Assignment
ASSIGN
CHANNELS/ROWS/OUTPUTS/SWITCHES
Rows, channels, outputs, and switches require assignment to
sections. As rows are assigned to each section, row numbers
automatically populate.
TO ASSIGN CLUTCH SECTION SWITCHES:
1. At the Clutch Sections screen, press the Arrow button.
2. Enter the total number of switches.
3. Enter the channel that corresponds with the section.
4. Enter the number of rows to be turned on/off by each
output/channel. The row numbers are sequentially assigned
to the left, center, and right outputs based on the # of
rows entered.
5. Enter the output assigned to the respective row.
6. Enter the switch assigned to the respective row that
identifies what switches on the row shutoff switch box enable
and disable planter sections or outputs. If a task controller is
used, manual switches are optional. If used, they serve as a
“Priority Off” function which will override the task controller
section state when the manual switch is in the off position.