68
TruVision Series 7 IP Camera Configuration Manual
Alarm inputs and outputs
To set up the external alarm input:
1. Click
Configuration
>
Event
>
Basic Event
>
Alarm Input
.
2. Choose the
Alarm Input No.
and the
Alarm Type
. The alarm type can be NO
(Normally Open) and NC (Normally Closed). Enter a name for the alarm input.
3. Set the arming schedule for the alarm input. See “To set up motion detection” for
more information.
4. Select the check box to select the actions.
Send Email
Send an email to a specified address when there is a motion
detection alarm.
Note:
You must configure email settings before enabling this
option. See “To set up the email parameters” on page 42 for
further information. If you want to send the event snapshot
together with the email, select the
Attached Snapshot
option.
Notify Alarm Recipient
Send an exception or alarm signal to remote management
software when an event occurs.
Upload to FTP/Memory
Card/NAS
Capture the image when an alarm is triggered and upload the
picture to NAS, Memory Card or FTP server.
Note
: To upload the snapshot to NAS, you must first configure
the NAS settings. See “NAS” on page 93” on page 91 for
further information.
To upload the snapshot to an FTP, you must first configure the
FTP settings. See “To define the FTP parameters” on page 41
for further information. Enable the
Upload Type
option.
To upload the snapshot to FTP and NAS when motion
detection or an alarm input is triggered, you must also
Enable
Event-triggered Snapshot
under the snapshot parameters.
See “Scheduled snapshot” on page 89 for further information.
Trigger Alarm Output
Trigger external alarm outputs when an event occurs. Select
“Select All” or each individual alarm output.
Note:
This option is only supported by cameras that support
alarm output.
Trigger Recording
Triggers the recording to start in the camera.
5. Click
Save
to save changes.
To set up alarm output:
1. Click
Configuration
>
Event
>
Basic Event
>
Alarm Output
.
2. Select one alarm output channel from the
Alarm Output
drop-down list. You can
also set a name for the alarm output.
3. Set the delay time to 5 s, 10 s, 30 s, 1 min, 2 min, 5 min, 10 min or manual. The
delay time refers to the time duration that the alarm output remains in effect after the
alarm occurs.
4. Set the arming schedule for the alarm input. See “To set up motion detection” on
page 62 for more information.