Bezique
1
Shower
inoperable, no water
flow.
2
Water too hot.
3
Water
temperature cycling
hot/cool at intervals.
4
Water too cool
or cold.
1.1
Interrupted power
supply.
1.2
Unit malfunction.
2.1
not enough water
flowing through the
shower.
2.2
blockage in supply.
2.3
Increase in ambient
water temperature.
3.1
Heater cycling on
outer temperature limiter.
4.1
Too much flow.
4.2
Water pressure below
minimum stated on rating
label.
4.3
Reduction in ambient
water temperature.
4.4
Electrical malfunction
or safety cut-out has
operated.
1.1.1
blown fuse or circuit breaker. Check
supply. Renew or reset fuse or circuit breaker. If it
fails again, consult a qualified electrician.
1.1.2
Power cut? Check other appliances and if
necessary, contact local Electricity Supply Co.
1.2.1
Have unit checked. Ring Customer
Service.
2.1.1
Increase the flow rate via temperature
control.
2.1.2
blocked showerhead — clean blocked
sprayplate.
2.2.1
Check if stop taps are fully open. Check if
blockage in inlet filter.
2.3.1
Switch to economy power setting and
readjust flow rate to give required temperature.
3.1.1
See
'Water too hot'
causes 2.1, 2.2 and 2.3
and their action/cures. If it continues, contact
Customer Service.
4.1.1
Reduce flow rate via temperature control.
4.2.1
Check low pressure indicator. If lit,
continue with remainder of checks. If not lit, see
4.1 & 4.4.
4.2.2
Is water supply mains or tank fed?
4.2.3
If tank fed, replumb to mains water
supply or see 4.2.5.
4.2.4
If mains fed, make sure the mains stop
valve is fully open and that there are no other
restrictions in the supply while shower is in use,
or see 4.2.5.
4.2.5
Fit a pump to give minimum pressure
— contact Customer Service for advice.
4.3.1
Switch to full power setting and readjust
the flow rate via the temperature control to give
required temperature.
4.4.1
Have unit checked by suitably qualified
electrician or contact Customer Service.
faulT fiNDiNG
ImpoRtANt:
Switch oFF the electricity at the mains supply and remove the circuit fuse before
attempting any fault finding inside the unit.
Problem/Symptom Cause
action/Cure