Bezique

iNTrODuCTiON

This book contains all the necessary fitting and 
operating instructions for your Triton bezique 
electric shower. Please read them carefully.
The shower installation must be carried out by a 
suitably qualified person and in the sequence of 
this instruction book.
Care taken during the installation will provide a 
long, trouble-free life from your shower.

SPECifiCaTiONS

Electrical

 

nominal power 

nominal power 

rating at 240V 

rating at 230V 

9.5kW 

 (40A MCb rating)  8.7kW 

 (40A MCb rating) 

10.5kW 

 (45A MCb rating)  9.6kW 

 (45A MCb rating)

Water

 

Inlet connection – 15mm diameter. 
Outlet connection – ½” bSP male thread.

Entry Points 

Water – bottom or back. 
Cable – top or back.

Materials 

backplate, cover, controls, showerhead – AbS. 
Sprayplate – Acetal. 
Elements – Minerally insulated corrosion resistant 
metal sheathing.

Dimensions 

Height 

 338mm 

Width 

 208mm 

Depth 

 95mm

Standards and Approvals 

Splashproof rating IPX4.
Complies with the requirements of current british 
and European safety standards for household 
and similar electrical appliances.
Complies with requirements of the british 
Electrotechnical Approvals board (bEAb).
Meets with Compliance with European 
Community Directives (CE).

aDViCE TO uSErS

The following points will help you understand 
how the shower operates:

a.

  The electric heating elements operate at a 

constant rate at your chosen power setting. It is the 
rate of the water passing through the heater can 
which determines the water temperature. (The 
slower the flow the hotter the water becomes, and 
the faster the flow, the cooler the water).

b.

  During winter the mains water supply will be 

cooler than in the summer, so the flow rate will 
vary between seasons at any one temperature 
setting. At different times of the year you may 
have to adjust the position of the temperature 
control to maintain your desired temperature 
setting.

c.

  The stabiliser valve minimises variations in 

shower temperature during mains water pressure 
changes. If changes in shower temperature are 
experienced during normal use, it will most 
likely be caused by the water pressure falling 
near to or below the minimum level. The drop 
in pressure may be due to water being drawn 
off at other points in the house whilst the 
shower is in use. If pressure drops appreciably 
below the minimum, the heating elements will 
automatically cut out. 

If ever the water becomes too hot and you 
cannot obtain cooler water, first check 
that the sprayplate in the showerhead has 
not become blocked.

DO nOT place items such as soap or shampoo 
bottles on top of the unit. Liquid could seep 
through the joint between the cover and 
backplate, and possibly damage the sealing 
rubber.

ImpoRtANt: 

When  first  installed  the 

unit  will  be  empty.  It  is  essential  the  unit 
should contain water before the elements 
are switched on. As this unit has electronic 
control,  it  is  vital  that  the  commissioning 
procedure is followed. Failure to carry out 
this operation will result in damage to the 
unit and will invalidate the guarantee.

Replacement parts can be ordered from Customer 

Service. See

 ‘spare parts’ 

for details and part numbers.

Due to continuous improvement and updating, 

specification may be altered without prior notice.

Содержание Bezique

Страница 1: ...low pressure power Installers please note these instructions are to be left with the user 2180225L March 2006 Installation and operating instructions Bezique electric shower...

Страница 2: ...cover 14 Fitting the riser rail 15 16 Fitting the hose and sprayehead 16 Operating the shower 17 18 Operating functions 19 Adjusting the showerhead 20 Cleaning the showerhead 21 Cleaning the inlet fil...

Страница 3: ...is sufficient 2 6 All plumbing connections must be completed before making the electrical connections 3 Electrical 3 1 The installation must comply with BS 7671 Requirements for electrical installatio...

Страница 4: ...water becomes and the faster the flow the cooler the water b During winter the mains water supply will be cooler than in the summer so the flow rate will vary between seasons at any one temperature s...

Страница 5: ...assembly 12 Thermal cut out main 13 Earth connection 14 Outlet temperature limiter 15 Trimplate Inside cover fig 2 16 Cover tags 17 Control PCB Pack contents Shower unit Five position showerhead Riser...

Страница 6: ...4 Check your consumer unit main fuse box has a main switch rating of 80A or above and that it has a spare fuse way which will take the fuse or mcb necessary for the shower fig 4 4 1 If your consumer...

Страница 7: ...those rooms must be protected by a 30mA RCD 9 The current carrying capacity of the cable must be at least that of the shower circuit protection see table B 9 1 To obtain full advantage of the power p...

Страница 8: ...al Water Authority or consult a competent plumber During periods of high ambient temperatures it may be necessary to select a low power setting to achieve your preferred shower temperature The water s...

Страница 9: ...fitted in the supply pipework to prevent back flow Pressure relief safety device A pressure relief device PRD is designed into the shower unit which complies with European standards The PRD provides a...

Страница 10: ...ed to be cut out in the trimplate and cover fig 9 If surface cable entry from the top is required then a small area will need to be cut out in the backplate fig 10 If installing a feed pipe from the r...

Страница 11: ...t building block you must use suitable wall plugs and an appropriate drill bit Screw top fixing screw into position leaving the base of the screw head protruding 6mm out from the wall Hook the backpla...

Страница 12: ...the shower flush out the pipework to remove all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris...

Страница 13: ...conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through conduit or in trunking or by embedding i...

Страница 14: ...the 10 way ribbon cable at this stage Carefully locate the cover tags into the guide pockets on the backplate and make sure the wires are not trapped Guide the cover into position so that the control...

Страница 15: ...flow and back again several times to release any trapped air from within the unit Once the flushing out has been completed switch off the electricity to the shower at the isolating switch The water w...

Страница 16: ...te and make sure the wires are not trapped Guide the cover into position so that the knob spindle locates correctly minor adjustment may be necessary to align the knob and spindle Should any difficult...

Страница 17: ...cut out on the bracket end fig 23 Locate the second bracket on top of the rail Check the rail is vertical then mark the centre hole and of the other two holes Remove the bracket and rail Drill and pl...

Страница 18: ...so it holds the dish at the required height on the rail Fitting the hose and Showerhead Feed the flexible hose through the appropriate soap dish opening fig 30 so that the dish acts as a retaining rin...

Страница 19: ...re control The centre button blue symbol is for cold water only Adjusting the temperature control at this setting will only increase or decrease the force of the water from the showerhead It will not...

Страница 20: ...numbers To increase the shower temperature Turn the temperature control clockwise this will decrease the flow of water through the shower and is indicated by higher numbers Note It is advisable to be...

Страница 21: ...operation Phased shutdown In use when the stop button is pressed power is switched off to the elements Water will continue to flow for a few seconds flushing out any remaining hot water This makes sur...

Страница 22: ...our shower is supplied with a five position showerhead with a rub clean face Five showerhead patterns are available fig 35 Adjust the spray pattern by turning the bezel on the showerhead in either dir...

Страница 23: ...anti clockwise fig 37 This movement may turn the cartridge assembly as well until it reaches a stop Hold the cartridge firmly and continue to twist anti clockwise Having loosened the sprayplate it ca...

Страница 24: ...pipe which is part of the solenoid valve fig 38 To gain access to the filter remove the trimplate then disconnect and remove the compression fitting Also depending on the incoming pipework arrangemen...

Страница 25: ...10 5kW 84500670 4 Stabiliser valve assembly 9 5kW 82600870 10 5kW 82200850 5 Solenoid valve assembly 83304130 6 Thermal cut out 22009860 7 PRD O ring 83301330 8 Outlet pipe assembly 85000130 9 Trimpla...

Страница 26: ...Ref Description Part No 11 5 mode showerhead 22010980 12 Wall bracket 83306160 13 Showerhead holder 83306190 14 Riser rail 7042409 15 Soap dish 22008960 16 Flexible hose 28100080 SPARE PARTS 11 12 13...

Страница 27: ...ps are fully open Check if blockage in inlet filter 2 3 1 Switch to economy power setting and readjust flow rate to give required temperature 3 1 1 See Water too hot causes 2 1 2 2 and 2 3 and their a...

Страница 28: ...s to normal Low pressure indicator extinguishes 6 1 1 Clean sprayplate and then fit a new PRD 6 2 1 Check for free passage through hose Replace hose if necessary and then fit new PRD 6 3 1 Fit new PRD...

Страница 29: ...Bezique 27...

Страница 30: ...Bezique 28...

Страница 31: ...Bezique 29...

Страница 32: ...order 2 By telephone quoting credit card MasterCard or Visa details 3 By website order www tritonshowers co uk Triton Standard Guarantee Triton Plc guarantee this product against all mechanical and e...

Отзывы: