faulT fiNDiNG
Problem/Symptom Cause
action/Cure
5
Shower varies
from normal
temperature to cold
during use.
6
Pressure relief
device has operated
(water ejected from
PRD tube).
5.1
Water pressure
has dropped below
minimum required.
Indicator lit.
6.1
blocked showerhead.
6.2
Twisted/blocked
flexible shower hose.
6.3
Showerhead
not removed while
commissioning.
5.1.1
Wait until the water pressure resumes to
normal. Low pressure indicator extinguishes.
6.1.1
Clean sprayplate and then fit a new PRD.
6.2.1
Check for free passage through hose.
Replace hose if necessary and then fit new PRD.
6.3.1
Fit new PRD. Commission unit with
showerhead removed.
Note:
Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.
In the unlikely event of a fault occurring please
contact triton customer service. do not remove
the shower from the installation.