Page 52
J-Series Data Radio – User Manual
Issue 09-10
eDiagnostics
eDiagnostics (also known as eDiags) is a feature of the TVIEW+ Diagnostics software that encapsulates the TVIEW+ Diagnostics protocol in an
Ethernet UDP/IP packet. Together with the eDiags server built into each J-Series radio, the user can monitor the J-Series Ethernet radios network
using the TVIEW+ Diagnostics software over an Ethernet LAN/WAN. A typical use diagram is shown below.
For more information on the features and benefits of the TVIEW+ Diagnostics software, please refer to the TVIEW+ Managesuite Suite Brochure
and for additional technical details, the TVIEW+ Diagnostics User Manual.
The operation of eDiags is as follows:
(1) The TVIEW+ Diagnostics software is installed on a PC and the system design provides Ethernet connectivity between the PC and the
Access Point of the J-Series Ethernet radio network.
(2) The TVIEW+ Diagnostics software on the PC is configured with the following items:
• Create a list (database) of J-Series radios that need to be polled for diagnostics. The IP address and eDiags listening ports
for each radio must be specified as well as the serial number of the radio. Other information can also be specified.
• Define a local listen port for incoming eDiags messages (ie: Diagnostics responses from J-Series radios)
(3) Each J-Series Ethernet radio needs to have eDiags configured and enabled.
• eDiags must be enabled (it is disabled by default)
• The eDiags local listen port must be configured. This is the port on which the eDiags server listens for incoming eDiags
polls from the TVIEW+ Diagnostics software.
•The eDiags remote IP address & port must be configured. This is the IP address of the PC running the TVIEW+ Diagnostics
software. The port is the eDiags listening port on the PC.
Содержание JR240