RESP_EXT_APP_CONFIG
This is the response message to the SET_EXT_APP_CONFIG (page 150) and
QUERY_CONFIG (page 161) message containing the Extended Application
Parameter values.
>RTKABCCCCCCDEFFFFFFGGGGGGHIJJJKKKLLMMNNO;ID=YYYYYYYY;
*ZZ<
A
TrimTrac Configuration Set
: ‘X’ = Extended Application
Parameters
B
Scheduled Report
Mode
. 0=None; 1=Daily; 2=Weekly
CCCCCC
Scheduled Report Time,
T18
. In Seconds (0-604799).
Note: This
is either the seconds into the day or into the week for the device to
schedule transmission of a STATUS_MESSAGE plus the most
recently logged
POSITION_REP, if any, when this feature is enabled.
If Scheduled
Report Mode
is set “0=None”, then enter 0.
D
In-Motion Polling.
0=Disabled; 1=OnDemand while in Motion. Note:
If set to “1=OnDemand while in Motion”, the unit is able to receive
and process data messages
ONLY while in motion regardless of
current state.
E
Anytime Polling.
0=Disabled; 1=Duty-Cycled while
in IDLE State;
2=Anytime OnDemand. See “Polling” section on page 39. Note:
If set to “2=Anytime OnDemand”, the unit is able to receive and
process data messages regardless of motion, current state or how
In-Motion Polling is set. If set “1=Duty-Cycled”, unit is able to
receive and process data messages while in QUERY or
whenever while Polling Duty-Cycle On-Time, T20, is running.
.
Default
0
. Note: In-Motion Polling is treated as always “1=Enabled”
when Anytime Polling is set to “2=Anytime OnDemand”.
FFFFFF
Polling Duty-Cycle Frequency,
T19
.
In Seconds (10-999990).
Note: Determines how frequently the Polling Duty-Cycle On-Time,
T20, timer is started if and only if the Anytime Polling is set
to
“1=Duty-Cycled while in
IDLE State”
and device is NOT in
motion.
Default
3600
. Note: Determines the frequency at which the
QUERY state is enabled while in the IDLE state if and only if the
Anytime Polling
is set to “1=Duty-Cycled”.
GGGGGG
Polling Duty-Cycle On-Time,
T20
.
In Seconds (0,
10-999990).
Note: Determines how long after expiration of Polling Duty-Cycle
Frequency, T19, timer that
the unit is able to
receive and process data
messages. A value of zero
causes
the QUERY Timeout, T5, value to
be used.
Default
60
.
H
Query Hold Flag.
0=Disabled; 1=Enabled.
Note: Unit attempts to
reconnect to the GSM network if the connection is lost during the
QUERY state prior to the expiration of QUERY Timeout,
T5.
I
Reserved.
0=Formerly “Extended
Motion Detection” in
TrimTrac
1.0 Not used in TrimTrac ProE.
JJJ
Position Report Transmit Attempts,
N1
.
0=Until T3 Expires; 1-
255=Number of Tx Attempts.
Содержание ProE Locator
Страница 83: ...TrimTrac ProE Locator Technical Manual v2 0e 65 Figure 19 External GPS Antenna Connected to TrimTrac ProE ...
Страница 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Страница 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Страница 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Страница 115: ...TrimTrac ProE Locator Technical Manual v2 0e 97 Figure 27 Other Message Processing in TRANSMIT ...
Страница 150: ...TrimTrac ProE Locator Technical Manual v2 0e 132 Default AT CTKY 10 10 10 10 0 300 60 0 0 0 0 1 0 ...
Страница 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Страница 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Страница 192: ...TrimTrac ProE Locator Technical Manual v2 0e 174 ZZ Checksum Table 78 RESP_EXT2_APP_CONFIG Message ...
Страница 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Страница 231: ...TrimTrac ProE Locator Technical Manual v2 0e 213 Figure 36 Vehicle Adapter Module Alert Wiring Diagram ...
Страница 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...