TrimTrac ProE Locator Technical Manual v2.0e
103
Operation of the TrimTrac ProE is altered depending upon the status of each monitored
device and status of the alert. By definition, an alert is considered “normal” when in the
condition as shown in Figure 36. Vehicle Adapter Module Alert Wiring Diagram on page
83 and all previous alerts have been cleared (more on clearing of alerts shortly).
An alert is said to have been “Initiated” when its status first changes from the
“0=Normal” to “1=Activated” condition. Initiating an alert is a random event that can
occur when the TrimTrac ProE is in any of its operational states (See Figure 23.
Summary TrimTrac Operational State Diagram). How the TrimTrac ProE modifies its
operational behavior is dependent upon the type of priority alert being initiated and in
what state the device happens to be in at the time of initiation.
When a High or Medium Priority switch or device changes from its normal condition for
200 mSeconds or more, or upon loss of external power in the case of the Medium Priority
alert, the associated alert is set to “1=Activated”. The exception to this a Low Priority
switch which must be held closed while motion is sensed before its status is changed to
“1=Activated”.
The status of an “Activated” alert will be set to “2=Sent” once the TrimTrac ProE has
successfully transmitted the associated message to the GSM network. Depending on the
priority of the alert, the TrimTrac ProE will operate in accordance with the associated
configuration unless otherwise instructed by the server application.
Because SMS text messaging or UDP provide no guarantee of delivery, just because the
TrimTrac ProE has successfully transmitted the alert message to the GSM network, there
is no guarantee that the server application has in turn received the transmitted alert
message. As such, the TrimTrac ProE will continue transmitting the alert messages until
it receives back from the server application an appropriately configured
SET_ALERT_STATE message (See 147), at which time, the alert status can be set
“3=Acknowledged”.
Finally, when the device that initiated the alert in the first place is returned to its
“normal” condition, then the alert can be “cleared” upon receipt of an appropriately
configured SET_ALERT_STATE message. If a “clear” command is sent before the
monitor switch or device is returned to its “normal” condition, then a new alert will be
initiated immediately and the clearing process will need to be repeated. If the alert mode
was set to “3=Monitor-only”, then the status of the monitored alert will be automatically
reset to “0=Normal” when the device is reset; however, no separate message to this effect
will be transmitted. The updated status of a monitor-only alert will simply be included in
the next report to be logged.
High Priority Alert Processing
An example of a High Priority Alert could be a manually operated switch or device that
requires immediate and continuous transmission of the resulting alert message until
acknowledged or cleared by the server application.
Содержание ProE Locator
Страница 83: ...TrimTrac ProE Locator Technical Manual v2 0e 65 Figure 19 External GPS Antenna Connected to TrimTrac ProE ...
Страница 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Страница 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Страница 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Страница 115: ...TrimTrac ProE Locator Technical Manual v2 0e 97 Figure 27 Other Message Processing in TRANSMIT ...
Страница 150: ...TrimTrac ProE Locator Technical Manual v2 0e 132 Default AT CTKY 10 10 10 10 0 300 60 0 0 0 0 1 0 ...
Страница 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Страница 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Страница 192: ...TrimTrac ProE Locator Technical Manual v2 0e 174 ZZ Checksum Table 78 RESP_EXT2_APP_CONFIG Message ...
Страница 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Страница 231: ...TrimTrac ProE Locator Technical Manual v2 0e 213 Figure 36 Vehicle Adapter Module Alert Wiring Diagram ...
Страница 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...