TrimTrac ProE Locator Technical Manual v2.0e
90
TriggerType event occurs or the next time the Polling Duty-Cycle
Frequency, T19, timer expires.
•
If the Scheduled Report Mode is set to either “1=Daily” or
“2=Weekly” the TriggerType will be set “4=Scheduled Report” upon
expiration of Scheduled Report Time, T18, timer regardless of the
Report Delay Flag setting.
•
If either of the Runtime meters have a threshold set to some value
other than “0 hours” and the accumulated runtime hours reach the
associated threshold, then the TriggerType will be set “5=Runtime
Meter” and the device will transition to the STATUS State.
•
If the Report Delay Flag is set “4=Tx Start/Stop, IDLE Status &
Exception Reports” and there has been no motion since the most
recently completed FIX State, then the TriggerType will be set
“6=Stop Report” and the device will transition to the STATUS State.
Alert Processing in the IDLE State:
Whenever one or more Vehicle Adapter or Control Module alerts are in some
condition status other than “0=Normal” or “3=Acknowledged”, and not mode set
“1=Disabled” or “3=Monitor-only”, alert processing during IDLE state shall be in
the following order:
1.
If HPA Status is set:
a.
Or becomes set to“1=Activated”, then set TriggerType to
“2=Exception Report Alert” and go to STATUS state;
b.
“2=Sent”:
i.
To FIX state if Position Age flag is set “1=Aged”; or
ii.
If Position Age flag is set “0=Current”, start HPA Idle
Timeout, T11. Upon expiration HPA Idle Timeout, T11, or
upon detection of subsequent motion, transition to STATUS or
FIX states, respectively.
2.
If MPA Status is set:
a.
Or becomes set to“1=Activated”, then set TriggerType to
“2=Exception Report Alert” and go to STATUS state;
b.
“2=Sent”:
i.
To FIX state if Position Age flag is set “1=Aged”; or
ii.
If Position Age flag is set “0=Current”, start MPA Idle
Timeout, T12. Upon expiration MPA Idle Timeout, T12, or
upon detection of subsequent motion, transition to STATUS or
FIX states, respectively.
3.
If LPA Status is set or becomes set to“1=Activated”, then set TriggerType to
“2=Exception Report Alert” and go to STATUS state.
Содержание ProE Locator
Страница 83: ...TrimTrac ProE Locator Technical Manual v2 0e 65 Figure 19 External GPS Antenna Connected to TrimTrac ProE ...
Страница 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Страница 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Страница 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Страница 115: ...TrimTrac ProE Locator Technical Manual v2 0e 97 Figure 27 Other Message Processing in TRANSMIT ...
Страница 150: ...TrimTrac ProE Locator Technical Manual v2 0e 132 Default AT CTKY 10 10 10 10 0 300 60 0 0 0 0 1 0 ...
Страница 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Страница 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Страница 192: ...TrimTrac ProE Locator Technical Manual v2 0e 174 ZZ Checksum Table 78 RESP_EXT2_APP_CONFIG Message ...
Страница 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Страница 231: ...TrimTrac ProE Locator Technical Manual v2 0e 213 Figure 36 Vehicle Adapter Module Alert Wiring Diagram ...
Страница 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...