TrimTrac ProE Locator Technical Manual v2.0e
157
SET_GPS_CONFIG
The SET_GPS_CONFIG message is used by the server application to set the
TrimTrac GPS parameter values in the TrimTrac ProE. When received the
TrimTrac ProE will send a RESP_GPS_CONFIG (page 157) message in
response. Please note that these GPS configuration parameters will seldom need
to be changed from default values. It is NOT recommended that they be changed
without first consulting with your Trimble representative.
>STKABBCCCDDDEEEF;PW=PPPPPPPP;ID=YYYYYYYY;*ZZ<
A
TrimTrac Configuration Set
:
‘G’ = GPS Parameters
BB
GPS Elevation Mask
.
In degrees (0-30)
. Default 5
CCC
GPS PDOP Mask
.
In tenths of PDOP (60 – 200)
. Default 120
DDD
GPS PDOP Switch
.
In tenths of PDOP (40 – 120)
. Default 60
EEE
GPS Signal Mask
.
In tenths of AMUs (10 – 80)
. Default 14
F
GPS Dynamics Mode
.
(Do
Not Change). Default 5
PPPPPPPP
Security Password
.
Always 8 alphanumeric characters, UPPER CASE
ONLY.
. Default 00000000
YYYYYYYY
Unit ID.
Always 8 alphanumeric characters, UPPER CASE ONLY
ZZ
Checksum.
Table 65, SET_GPS_CONFIG Message
SET_MODULE_APP_CONFIG
This message is used by the server to set the Application Parameter Values
associated with the Vehicle Adapter and Control Modules. When received the
TrimTrac ProE will send a RESP_MODULE_APP_CONFIG (page 180) message
in response.
>STKABBBBBBCCCCCCDDDDDDEEEEEEFFFFFFGGGGGGHHHHHHIIIJJJK
KKLMN;PW=PPPPPPPP;ID=YYYYYYYY;*ZZ<
A
MODULE-only Configuration Set:
‘Y’ = MODULE-only
Parameters
BBBBBB
HPA Idle Timeout, T11
. In Seconds (10-999990) Default 10
CCCCCC
MPA Idle Timeout, T12.
In Seconds (10-999990). Default 10
DDDDDD
HPA Delay Timeout, T13.
In Seconds (10-86400). Default 10
EEEEEE
MPA Delay Timeout, T14.
In Seconds (10-86400). Default 10
FFFFFF
HPA Transmit Timeout, T15.
0=Infinity; Else in Seconds (10-
999990). Default 0
GGGGGG
MPA Transmit Timeout, T16.
0=Infinity; Else in Seconds
(10-999990) If not set 0-Infinity, should be set no lower than
300 Seconds. Default 300
HHHHHH
HPA Query Timeout, T17.
In Seconds (10-3600). Default 60
III
HPA Transmit Attempts,
N5
.
0=Until T15 Expires; 1-
255=Number of Tx Attempts before T15 expires. Default 0.
Содержание ProE Locator
Страница 83: ...TrimTrac ProE Locator Technical Manual v2 0e 65 Figure 19 External GPS Antenna Connected to TrimTrac ProE ...
Страница 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Страница 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Страница 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Страница 115: ...TrimTrac ProE Locator Technical Manual v2 0e 97 Figure 27 Other Message Processing in TRANSMIT ...
Страница 150: ...TrimTrac ProE Locator Technical Manual v2 0e 132 Default AT CTKY 10 10 10 10 0 300 60 0 0 0 0 1 0 ...
Страница 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Страница 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Страница 192: ...TrimTrac ProE Locator Technical Manual v2 0e 174 ZZ Checksum Table 78 RESP_EXT2_APP_CONFIG Message ...
Страница 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Страница 231: ...TrimTrac ProE Locator Technical Manual v2 0e 213 Figure 36 Vehicle Adapter Module Alert Wiring Diagram ...
Страница 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...