TrimTrac ProE Locator Technical Manual v2.0e
89
2.
When the unit enters the IDLE State and no motion has been detected, it starts
the IDLE Timeout, T1, and waits for a TriggerType event to occur. (LED
OFF, unless Anytime Polling mode is set “2=Anytime OnDemand”.)
3.
Upon the occurrence of a TriggerType event, the unit will wake up and
transition out of the IDLE state based upon the TriggerType event and the
current configuration settings as follows:
•
Upon expiration of the IDLE Timeout, T1, the TriggerType is set
“0=IDLE Timeout, T1”, the TrimTrac ProE will transition to the
STATUS state (bypassing the FIX state).
•
If motion is detected while in the IDLE state, the TrimTrac ProE will
activate the Static Motion Filter Timeout, T7, and apply the Static
Motion Filter Counter, N3. (Rapid LED Blinking)
If there is sufficient continued motion, the TriggerType becomes set
“1=Motion Detected” and the unit will transition to the FIX State if the
Motion Report Flag is set “0=None” or to the STATUS state if the
Motion Report Flag is set “1=Report IDLE Motion”. If there is
insufficient motion to satisfy the Static Motion Filter Counter, N3,
while the Static Motion Filter Timeout, T7, is running, then the unit
will return to the IDLE state sleep mode and wait for a subsequent
TriggerType event to occur.
•
If an alert status is in some state other than “0=Normal” or “4=Monitor
Activated” or upon an initial Geofence violation, then the TriggerType
shall be set “2=Exception Report Alert” and the device shall transition
from the IDLE State in accordance with its current configuration. See
the section below for more details on input alert processing.
•
If the Anytime Polling is set to “2=Anytime OnDemand”, the unit
keeps the GSM modem operational and the device is ready to receive
messages from the sever at any time while the IDLE Timeout, T1, is
running (Continuous Rapid LED Blinking). Upon receipt of any data
messages, the TriggerType is set “3=Query” and the unit transitions
immediately to the QUERY state to process any such received
messages.
•
If the Anytime Polling is set to “1=Duty-Cycled”, the TrimTrac ProE
will power duty-cycle the GSM modem on and off during the IDLE
state. Each time the Polling Duty-Cycle Frequency, T19, timer
expires, the GSM modem will power up and the Polling Duty-Cycle
On-Time, T20, will start (Rapid LED Blinking). The GSM modem
hardware will remain on until the expiration of Polling Duty-Cycle
On-Time, T20, or a query message is received. Upon receipt of any
query messages, the TriggerType is set “3=Query” and the unit
transitions immediately to the QUERY state to process any such
received messages; else it goes back into IDLE sleep until the next
Содержание ProE Locator
Страница 83: ...TrimTrac ProE Locator Technical Manual v2 0e 65 Figure 19 External GPS Antenna Connected to TrimTrac ProE ...
Страница 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Страница 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Страница 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Страница 115: ...TrimTrac ProE Locator Technical Manual v2 0e 97 Figure 27 Other Message Processing in TRANSMIT ...
Страница 150: ...TrimTrac ProE Locator Technical Manual v2 0e 132 Default AT CTKY 10 10 10 10 0 300 60 0 0 0 0 1 0 ...
Страница 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Страница 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Страница 192: ...TrimTrac ProE Locator Technical Manual v2 0e 174 ZZ Checksum Table 78 RESP_EXT2_APP_CONFIG Message ...
Страница 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Страница 231: ...TrimTrac ProE Locator Technical Manual v2 0e 213 Figure 36 Vehicle Adapter Module Alert Wiring Diagram ...
Страница 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...