88
immediately. If in FIX or TRANSMIT, then go to STATUS upon
completion of current FIX or TRANSMIT state (Note: This allows the
device to complete a “fresh” fix or complete sending any current messages
prior to processing the new LPA).
Alerts can be changed to:
1.
“2=Sent” from “1=Activated” during the TRANSMIT state if and only if
the GSM protocol software has confirmed that the message has been
successfully transmitted to the GSM network.
2.
“3=Acknowledged” from “1=Activated” or “2=Sent” only upon the
receipt of an appropriate SET_ALERT_STATE message or, if the Alert
Mode is set “2=Network Acknowledgement”, upon confirmation from the
GSM protocol software that the message has been successfully transmitted
to the GSM network.
3.
“0=Normal” from “1=Activated”, “2=Sent” or , “3=Acknowledged” only
upon the receipt of an appropriate SET_ALERT_STATE message;
provided, however, whatever condition that triggered the original alert has
been cleared. If the alert mode has been configured as “3=Monitor-only”,
then correcting whatever condition that triggered the original alert will
cause the alert status to be set back to “0=Normal”.
Using a Provisioning Module to silence an alert by setting the offending priority
alert mode to “1=Disable” will not clear the underlying alarm condition.
Therefore, if the alert modes are later set back to “0=Automatic”, either through
the use of a Provisioning Module or by sending the device an
SET_MODULE_APP_CONFIG message, the device will resume transmitting the
associated alert messages. The underlying alert monitoring software can only be
reset or cleared by sending the device the appropriate SET_ALERT_STATE
message.
IDLE State
The IDLE State is the state that the device enters when it goes to sleep waiting for
a TriggerType event to occur. Upon the occurrence of any TriggerType event, the
unit will transition from IDLE in accordance with TriggerType and current
configuration settings. While in the IDLE state, assuming default configuration,
all hardware is turned off except for the Motion Sensor Wakeup Logic and the
RTC; provided, however, if the Anytime Polling is set to either “1=Duty-Cycled”
or “2=Anytime OnDemand”, then the GSM hardware and software will operate
some or all of the time and the unit is able to communicate during IDLE.
1.
When the unit enters the IDLE State it checks if motion has been detected
since the device last exited the FIX State. If yes, the TriggerType is set
“1=Motion Detected” and the device immediately transitions to the FIX State
bypassing all of the other IDLE state checks detailed below.
Содержание ProE Locator
Страница 83: ...TrimTrac ProE Locator Technical Manual v2 0e 65 Figure 19 External GPS Antenna Connected to TrimTrac ProE ...
Страница 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Страница 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Страница 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Страница 115: ...TrimTrac ProE Locator Technical Manual v2 0e 97 Figure 27 Other Message Processing in TRANSMIT ...
Страница 150: ...TrimTrac ProE Locator Technical Manual v2 0e 132 Default AT CTKY 10 10 10 10 0 300 60 0 0 0 0 1 0 ...
Страница 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Страница 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Страница 192: ...TrimTrac ProE Locator Technical Manual v2 0e 174 ZZ Checksum Table 78 RESP_EXT2_APP_CONFIG Message ...
Страница 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Страница 231: ...TrimTrac ProE Locator Technical Manual v2 0e 213 Figure 36 Vehicle Adapter Module Alert Wiring Diagram ...
Страница 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...