Configuration Messages
The following messages are sent to the TrimTrac ProE to configure application,
GPS and GSM parameters and to set Vehicle Adapter or Control Module alert and
application parameters.
SET_ALERT_STATE
This message is sent to the TrimTrac ProE to acknowledge or clear alert states;
provided, however, that the TrimTrac ProE is connected to a Vehicle Adapter or
Control Module. When received the TrimTrac ProE will send a
RESP_ALERT_STATE (page 169) message in response, UNLESS:
1.
the SET_ALERT_STATE messages attempts to Clear an alert before all
activated inputs have been returned to their normal non-alert conditions, in
which case, no RESP_ALERT_STATE message will be sent. Instead, a
new alert message will be generated.
2.
If battery powered, sending the device a SET_ALERT_STATE message
will have no effect and not cause a RESP_ALERT_STATE message to be
returned.
>STKABCD;PW=PPPPPPPP;ID=YYYYYYYY;*ZZ<
A
Always ‘L’:
Indicates alert state setting
B
HPA Status
:
‘X’ = Do not care, ‘3’ = Ack, ‘0’ = Clear
C
MPA Status
:
‘X’ = Do not care, ‘3’ = Ack, ‘0’ = Clear
D
LPA Status
:
‘X’ = Do not care, ‘3’ = Ack, ‘0’ = Clear
PPPPPPPP
Security Password
.
Always 8 alphanumeric characters, UPPER
CASE ONLY.
. Default 00000000
YYYYYYYY
Unit ID.
Always 8 alphanumeric characters, UPPER CASE ONLY
ZZ
Checksum.
Table 57, SET_ALERT_STATE Message
Sample SET_ALERT_STATE Message to ACKNOWLEDGE alerts:
>STKL333;PW=00000000;ID=00000000;*16<
Sample SET_ALERT_STATE Message to CLEAR all alerts:
>STKL000;PW=00000000;ID=00000000;*15<
NOTE: Sending a Clear command before returning all conditions to their normal, non-
alert states will re-initiate the alert message sequence. If you wish to silence an activated
alert before the monitored device or condition have been restored to their normal non-
alert state, then send an acknowledgement SET_ALERT_STATE message. This will not
clear the alert, but it will stop re-transmissions until the condition is cleared.
Содержание ProE Locator
Страница 83: ...TrimTrac ProE Locator Technical Manual v2 0e 65 Figure 19 External GPS Antenna Connected to TrimTrac ProE ...
Страница 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Страница 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Страница 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Страница 115: ...TrimTrac ProE Locator Technical Manual v2 0e 97 Figure 27 Other Message Processing in TRANSMIT ...
Страница 150: ...TrimTrac ProE Locator Technical Manual v2 0e 132 Default AT CTKY 10 10 10 10 0 300 60 0 0 0 0 1 0 ...
Страница 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Страница 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Страница 192: ...TrimTrac ProE Locator Technical Manual v2 0e 174 ZZ Checksum Table 78 RESP_EXT2_APP_CONFIG Message ...
Страница 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Страница 231: ...TrimTrac ProE Locator Technical Manual v2 0e 213 Figure 36 Vehicle Adapter Module Alert Wiring Diagram ...
Страница 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...