TrimTrac ProE Locator Technical Manual v2.0e
129
AT+CTKX?
+CTKX: <Scheduled Report Mode>,<Scheduled Report Time, T18>,<In-Motion
Polling>,<Anytime Polling>,<Polling Duty-Cycle Frequency, T19>,<Polling
Duty-Cycle On-Time, T20>,<Query Hold Flag>,<Reserved>,<Position Report
Transmit Attempts, N1>,<Status Message Transmit Attempts, N2>,<Static Motion
Filter Counter, N3>,<Dynamic Motion Filter Timeout, T21>,<Dynamic Motion
Filter Counter, N4>,<Motion Sensor Override>
OK
<Scheduled Report
Mode
>
0=None; 1=Daily; 2=Weekly. Default
0
<Scheduled Report Time,
T18
>
In Seconds (0-604799).
Note: This is either the seconds
into the day or into the week for the device to schedule
transmission of a STATUS_MESSAGE plus the most
recently logged
POSITION_REP, if any, when this feature
is enabled. If Scheduled
Report Mode
is set “0=None”,
then enter 0. Default
0
<In-Motion Polling>
0=Disabled; 1=OnDemand while in Motion. Note: If set to
“1=OnDemand while in Motion”, the unit is able to receive
and process data messages
ONLY while in motion
regardless of current state.
Default
0
<Anytime Polling>
0=Disabled; 1=Duty-Cycled while
in IDLE State;
2=Anytime OnDemand. See “Polling” section on page
39. Note: If set to “2=Anytime OnDemand”, the unit is
able to receive and process data messages regardless of
motion, current state or how In-Motion Polling is set.
If set “1=Duty-Cycled”, unit is able to receive and
process data messages while in QUERY or whenever
while Polling Duty-Cycle On-Time, T20, is running.
.
Default
0
<Polling Duty-Cycle
Frequency,
T19
>
In Seconds (10-999990).
Note: Determines how frequently
the Polling Duty-Cycle On-Time, T20, timer is started if and
only if the Anytime Polling is set
to “1=Duty-Cycled
while in
IDLE State”
and device is NOT in motion.
Default
3600
<Polling Duty-Cycle On-
Time,
T20
>
In Seconds (0,
10-999990).
Note: Determines how long
after expiration of Polling Duty-Cycle Frequency, T19,
timer that
the unit is able to
receive and process data
messages. A value of zero
causes
the QUERY Timeout,
T5, value to
be used.
Default
60
<Query Hold Flag>
0=Disabled; 1=Enabled.
Note: Unit attempts to reconnect to
the GSM network if the connection is lost during the
QUERY state prior to the expiration of QUERY Timeout,
T5.
Default
0
<Reserved>
0=Formerly “Extended
Motion Detection” in
TrimTrac 1.0
Not used in TrimTrac ProE.
Default
0
Содержание ProE Locator
Страница 83: ...TrimTrac ProE Locator Technical Manual v2 0e 65 Figure 19 External GPS Antenna Connected to TrimTrac ProE ...
Страница 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Страница 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Страница 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Страница 115: ...TrimTrac ProE Locator Technical Manual v2 0e 97 Figure 27 Other Message Processing in TRANSMIT ...
Страница 150: ...TrimTrac ProE Locator Technical Manual v2 0e 132 Default AT CTKY 10 10 10 10 0 300 60 0 0 0 0 1 0 ...
Страница 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Страница 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Страница 192: ...TrimTrac ProE Locator Technical Manual v2 0e 174 ZZ Checksum Table 78 RESP_EXT2_APP_CONFIG Message ...
Страница 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Страница 231: ...TrimTrac ProE Locator Technical Manual v2 0e 213 Figure 36 Vehicle Adapter Module Alert Wiring Diagram ...
Страница 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...