Revision: 0
FlexxPump1 B
User Manual
44
EN-
7.2
Cartridge and battery change
Changing the lubricant cartridge of the FP1 B is very easy and takes place in four
steps.
In the present version of a battery-powered FP1 B, in addition to changing the cartrid-
ge, the battery has to be changed at the same time. The cartridge only needs to be
changed if it is empty, the battery is empty or the service life of the lubricant has been
exceeded. The cartridge and battery can be changed during normal operation of the
FP1 B.
FP1 B has a fault (Error E1 or Error E3); the red LED flashes every 5 seconds.
OR
The FP1 B battery is completely discharged, the LCD is dark (OFF is not displayed).
NOTICE
A used lubricant cartridge must not be replaced on the FP1 B,
as the integrated stroke counter of the FP1 B is automatically
reset by the cartridge sensor after a cartridge has been remo-
ved.
§
Only use full lubricant cartridges.
NOTICE
Only use original lubricant cartridges with lubricant approved
by the manufacturer.
§
Observe the maximum shelf life of lubricant filled in cartridges.
NOTCE
It is not possible to refill empty or opened lubricant cartridges.
NOTICE
Make sure you use the same lubricant in the new cartridge that
is already in use.
§
Compare the data on the lubricant cartridge.
The battery of the FP1 B must be replaced at the same time as
the lubricant cartridge!
§
Observe the safety instructions for the battery.