Revision: 0
FlexxPump1 B
User Manual
20
EN-
Emptying time Et = 6
The emptying time of one (1) cartridge is 6 months.
The default settings in the Empty-Time-Mode result in an emptying time (service life)
of 6 months for a full 125 ml lubricant cartridge, provided that the FP1 B is permanently
switched on and no special dispensations have been made. Within approx. 5.6 hours,
the FP1 B will deliver one donation per stroke (0.16 cm³).
Verify that the default settings are appropriate for your application and that the lubri-
cation point is supplied with the correct amount of lubricant per time unit.
If this is the case, you can operate the FP1 B with the default settings in the Emp-
ty-Time-Mode Et.
If this is
not
the case, change the values for the emptying time t accordingly; see chap-
ter 6.3.9 for an explanation of how to make these changes.
To use FP1 B, it must first be properly mounted and installed and then switched on.
Installation is very simple and described in detail in chapter 5.2; switching on is descri-
If you order a special version of FP1 B from the factory, the information contained in
the supplement is authoritative for you!
6.2.2 Default setting operating mode Empty-Time-Mode Et