Revision: 0
FlexxPump1 B
User Manual
25
EN-
Display in LCD Meaning
Chapter
dark
Battery not connected; battery completely discharged
OFF
FP1 B is switched off
On
FP1 B is ready for operation; FP1 B dispenses lubricant
in accordance to the operating mode and the set values
Errors
E1
Error E1 (Empty cartridge / Cartridge error)
E2
Error E2 (Overload)
E3
Error E3 (Undervoltage, battery empty)
E4
Error E4 (serious mistake)
Sub-Menu
INF
INF-Menu
/
b01
Firmware version of the FP1 B
h06
Currently set value of the dispensing time h
c01
Currently set value of the number of strokes c
6
Currently set value of the emptying time Et
SET SET-Menu
-h-
Operating mode Hour-Mode
Et
Operating mode Empty-Time-Mode
RUN
RUN-Menu
01...35
During the manually triggered active RUN command
("Quick-Check"/special donation), the LCD displays the
approximate back pressure in bar. In addition, the green
LED lights up.
PRO
PRO-Menu
/
h1...99
Adjustable setting of the dispensing time h
c1...10
Adjustbale setting of the number of strokes c
1...24
Adjustabe setting of the emptying time Et
FIL
FIL-Menu
01...35
During the manually triggered active FIL command, the
LCD displays the approximate back pressure in bar. In
addition, the green LED lights up.
Clr
If the process is aborted during the FIL command, Clr
appears first.