Revision: 0
FlexxPump1 B
User Manual
31
EN-
6.3.5 INF-Menu operating mode Empty-Time-Mode Et
The INF-Menu is used to inform the user about the firmware used in the FP1 B and
the settings made and currently active (value of the adjustable variable Et that can be
changed in the PRO-Menu).
In the INF-Menu nothing can be changed by the user. The values of the parameters are
displayed in a fixed order.
b
Alphanumerical name of the FP1 B firmware
Et
set value of the variable Et emptying time in months
125
value of the size of the lubricant cartridge
Remove the activation and programming key from the bottom of FP1 B and place it
on the action area.
Hold the activation and programming key on the action surface. The yellow LED lights
up. Leave the activation and programming key on the action area until INF is displayed
in the LCD. Remove the activation and programming key from the action area as long
as INF is displayed in the LCD. The yellow LED disappears; the LCD flashes together
with the green LED twice.
Ü
FP1 B informs you optically on the LCD about the set values.
Insert the activation and programming key into the hole provided on the underside of
the FP1 B.
The INF-Menu can only be accessed from the OFF mode (FP1 B is switched off).
When you have entered the INF-Menu, you will return to the OFF mode.