Changing the value of the dispensing time h:
If you want to change the value of the dispensing time h, move the activation and
programming key back to the action area.
Ü
In the LCD the next higher (h
is
+ 1) adjustable value of the dispensing time h is
displayed. The green LED lights up as long as the activation and programming key is
on the action surface; the other values of the dispensing time h run through one after
the other. However, you can also remove the activation and programming key from the
action area and bring it back to the action area shortly afterwards to reach each value
one after the other. If the final value of the dispensing time h of h=99 is reached and no
value has been selected, the menu returns to h=01 and the cycle can be restarted.
As long as the new value you choose for the dispensing time h (h
new
) is displayed in
the LCD, remove the activation and programming key from the action area.
Ü
The yellow LED disappears, the green LED and the LCD flash 2x. The selected new
value (h
new
= h
is
) of the dispensing time h has now been accepted. The submenu will
now automatically take you to the values of the number of cycles c.
No changing of the value of the dispensing time h:
If you do not want to change the value of the dispensing time h, the activation and
programming key must remain removed from the action area immediately after entering
the PRO-Menu.
Ü
The LCD as well as the green LED flashes twice and the dispensing time h is
displayed in the LCD. The submenu now automatically takes you to the values of the
number of cycles.
The LCD now displays the currently set value of the number of cycles c (c
is
). Now you
have the possibility to change the values of the number of cycles c.
Changing the value of the number of cycles c:
If you want to change the value of the number of cycles c, move the activation and
programming key back to the action area.
Ü
In the LCD the next higher (c
is
+ 1) adjustable value of the number of cycles c is
displayed. The green LED lights up as long as the activation and programming key is
on the action surface; the other values of the number of cycles c run through one after
the other. However, you can also remove the activation and programming key from the
action area and bring it back to the action area shortly afterwards to reach each value
one after the other. If the final value of the number of cycles c of c=10 is reached and
no value has been selected, the menu returns to c=01 and the cycle can be restarted.
As long as the new value you choose for the number of cycles c (c
new
) is displayed in
the LCD, remove the activation and programming key from the action area.
Ü
The yellow LED disappears, the green LED and the LCD flash 2x. The selected new
value (c
new
= c
is
) of the dispensing time h has now been accepted.
No changing of the value of the number of cycles c:
If you do not want to change the value of the number of cycles c, the activation and
programming key must remain removed from the action area immediately after entering
the PRO-Menu.