Revision: 0
FlexxPump1 B
User Manual
34
EN-
6.3.7 RUN-Menu
The RUN-Menu is used for manual activation of the FP1 B. A special donation from
FP1 B can be triggered in this way. This function can, for example, be used for the
advantageous "Quick Check" to manually check the condition of the lubrication point.
FP1 B carries out a special donation after triggering the RUN function. During the stro-
ke, the back pressure detected by the integrated microelectronics is displayed in the
LCD as an approximate value in bar.
There is no fault or error at FP1 B.
Remove the activation and programming key from the bottom of FP1 B and place it
on the action area.
Hold the activation and programming key on the action surface. The yellow LED lights
up. Leave the activation and programming key on the action area until RUN is display-
ed in the LCD. Remove the activation and programming key from the action area as
long as RUN is displayed in the LCD. The yellow LED disappears.
Ü
The LCD flashes together with the green LED twice. The FP1 B starts to pump the
lubricant to the outlet (special donation or "Quick-Check").
Insert the activation and programming key into the hole provided on the underside of
the FP1 B or repeat the special dispenser ("Quick-Check") if necessary.
Observe the back pressure values displayed on the LCD if they are of interest to
you.
During the dispensing process, the green LED lights up; in addition, the counterpres-
sure for the stroke is displayed in the LCD.
The RUN-Menu can only be reached from the ON mode (FP1 B switched on). When
you have entered the RUN-Menu, you will return to the ON mode.