Crimp Verification
Section 3
TAC
·
7X
MANUAL
1. Introduction
2. Initial Crimp
Verification
Initial and periodic crimp verifications must be made in order to be certain
a given TAC is crimping properly. Once a TAC is set-up and crimp
verification accomplished, the device will normally complete hundreds of
thousands of acceptable crimps before indenter adjustment or
replacement is necessary.
However, as in all precision equipment, something can malfunction, or the
indenters may inadvertently be subjected to a hard substance and the
resulting crimp not meet acceptable parameters. Therefore, it is
recommended that the Crimp Verification procedure be performed at least
monthly. A system of "spot checks" can also be established to verify
acceptable crimps.
The Initial Crimp Verification should be performed immediately after the
TAC has been set-up (Section 2). Although the procedure is the same as
all other verification tests, it affords the user an opportunity to record data
before the machine has been used extensively. Read and understand
Section 4, Operating Procedures, before performing the verification. This
paragraph details the procedure to verify TAC's with a fixed "G" dimension
and with an operator-selectable "G" dimension.
Perform the following steps to verify acceptable crimps:
WARNING
Before the funnel cover plate or the cylinder arbor cover plate
is removed, DISCONNECT the air supply
from the sleeve valve. INJURY COULD RESULT ! !
Step 1.
Open the sleeve valve.
Step 2.
Disconnect the air supply from the sleeve valve.
Step 3.
Refer to Figure 3-1.
Step 4.
Remove the four button head socket cap screws securing the
crimp cylinder arbor cover plate.
Содержание TAC-7AE
Страница 6: ...Figure 1 1 TAC 7X Front View ...
Страница 8: ... Figure 1 2 Wire Insertion Through Funnel ...
Страница 12: ...Figure2 1 Pneumatic Hook Up ...
Страница 14: ... Fiqure 2 4 Track Drop Tube Escapement ESCAPEMENT SYSTEM _ _ _ BR ASSEMBL I TRA ...
Страница 18: ... ARBOR COVER PLA TE REMOVED Figure 3 1 Crimp Cylinder Arbor Open ...
Страница 20: ... ARBOR COVER PLAT E REMOVED Figure 3 2 Crimp Cylinder Arbor Closed ...
Страница 23: ... Crimp Inspection Points Improper Crimps ...
Страница 33: ...Figure 6 1 TAC 7X Components ...
Страница 34: ...Figure 6 2 Control Box Components Figure 6 2 TAC 7X Components Right View ...
Страница 35: ...PLC Controller Switching Power Supply Vibratory Feed Controller Figure 6 3 TAC 7X Components Left View ...
Страница 37: ...Figure 6 3 Contact Track Feed Air Adjustments ...
Страница 42: ... Figure 6 4 Indenter Plate Removal ...
Страница 43: ...HOSE CLAMP CAREFULL Y REMOVE Figure 6 5 Indenter Replacement ...
Страница 47: ...Figure 6 6 Indenter Adjustment ...
Страница 52: ...TAC 7X Pneumatic Diagram ...