TAC-7X
MANUAL
Step 6.
Open the funnel and observe if a contact is present. If
contact is present, let the funnel close and proceed to Step
7. If no contact is present, close the funnel and depress the
first part switch again, and repeat this step.
NOTE
The funnel should be closed during normal operation when
inserting a conductor.
Step 7.
Obtain a properly stripped conductor or coil of properly
stripped conductors. Select the proper "G" dimension
setting (if applicable). See Table 4-1.
TABLE 4-1. EXTERNAL "G" SELECTIONS.
SETTING # = WIRE SIZE #
For 22 gauge contacts:
1 = 26 gauge
2 = 24 gauge
3 = 22 gauge
For 20 gauge contacts:
4 = 24 gauge
5 = 22 gauge
6 = 20 gauge
Step 8.
Carefully and smoothly insert a conductor into the funnel,
being careful all conductor strands enter the funnel.
NOTE
Conductor strands do not have to be twisted together, but
they do have to enter the funnel parallel to one another.
Содержание TAC-7AE
Страница 6: ...Figure 1 1 TAC 7X Front View ...
Страница 8: ... Figure 1 2 Wire Insertion Through Funnel ...
Страница 12: ...Figure2 1 Pneumatic Hook Up ...
Страница 14: ... Fiqure 2 4 Track Drop Tube Escapement ESCAPEMENT SYSTEM _ _ _ BR ASSEMBL I TRA ...
Страница 18: ... ARBOR COVER PLA TE REMOVED Figure 3 1 Crimp Cylinder Arbor Open ...
Страница 20: ... ARBOR COVER PLAT E REMOVED Figure 3 2 Crimp Cylinder Arbor Closed ...
Страница 23: ... Crimp Inspection Points Improper Crimps ...
Страница 33: ...Figure 6 1 TAC 7X Components ...
Страница 34: ...Figure 6 2 Control Box Components Figure 6 2 TAC 7X Components Right View ...
Страница 35: ...PLC Controller Switching Power Supply Vibratory Feed Controller Figure 6 3 TAC 7X Components Left View ...
Страница 37: ...Figure 6 3 Contact Track Feed Air Adjustments ...
Страница 42: ... Figure 6 4 Indenter Plate Removal ...
Страница 43: ...HOSE CLAMP CAREFULL Y REMOVE Figure 6 5 Indenter Replacement ...
Страница 47: ...Figure 6 6 Indenter Adjustment ...
Страница 52: ...TAC 7X Pneumatic Diagram ...