33-46-00
AS9100 Certified
Rev G
26-Mar-2014
Q. Bonding Test
(1) Measurement of the specified resistance values is made with a specially calibrated four pole
bonding tester.
Figure 98 - Trakkabeam® Electrical Bond Measuring Points
Table 26 - Trakkabeam® Electrical Bond Measurements
Description
Measuring
Points
Value
(m
Ω
)
From
To
Dovetail to lamp assembly.
1
2
<10
Dovetail to C clamp guide plate cap screw.
1
3
<5
Dovetail to dovetail power connector.
1
4
<1
Dovetail to dovetail control connector.
1
5
<1
Dovetail to azimuth bonding point.
1
6
<2
G020a
3
2
4
5
6
1
AIRBUS HELICOPTERS: CMM L334M6304E01 ISSUE: B PAGE 149 OF 165