α
Post bracket
A
B
Hinge
Post
D
C
E
Enlarge
F
R
S
Gate bracket
Base plate
(close position)
>0
Gate
Stop block
(open position)
5-10mm
α
90°
105°
A
B
135
160
130
130
D(min)
90
90
E
85
85
F(min)
R
65
S
635
635
7. Mechanical / Installation
Begin with both operators unlocked. Next identify if this will be a “push to open” or a “pull to open”
installation. In either configuration, the gate is mounted on one face of the mounting post, and the
operator is mounted on the face 90 degrees from it. Below are schematics of both “push to open”
and “pull to open” configurations.
As shown in the diagram below, correctly mounting geometry assures that the desired degrees of
swing are achieved, that the gate speed is correct, and that the operator and gate will operate
properly and have a long life.
Fig.1 Pull to open mounting geometry