ZK1800
SWING GATE OPERATOR USER’S MANUAL
12
Fig.14
Stop block
–open position
After the gate reaches the desired angle (90
°
or 105
°
), ensure 5-10mm space exists
between the gate and stop block See Fig.1 or Fig.2. This margin is required to prevent the
gate from bumping on the stop block.
Fix the stop block to the ground with expansion bolts, add pad if necessary.
After mounting the operator, with the key unlocked, move the gate, verify that it stops at the
proper position.
Electric lock
An electric lock is provided for installation for gate lengths greater than 1.5 meters.
To install the base plate of the lock, place the base plate between the two gates, determine
the location, mark and drill the holes.
Fix the base plate to the ground with 3 screws, make sure the gate is higher than base plate
and that the lock pin can fit tightly in the hole in the plate.
Weld the steel plate of the lock to the primary gate, and then fix the lock to the steel plate.
See Fig.15 to determine the height of the electric lock.
3
4
1
Pin
2
Circlip
3
Gate operator
4
Sping washer ,plane washer
and lock nut M12
Fix the gate operator on the brackets, make sure
that the operator is level.
1
2