ZK1800
SWING GATE OPERATOR USER’S MANUAL
10
If it is not possible to maintain the quotas indicated in the table see Fig.7, different measurements
should be calculated with reference to the following items:
For α=90°, F≥R
For
α=105°, F≥65mm
The difference between A and B must not exceed 30mm.
It is important to maintain the quota D, otherwise the gate will bump the post.
The thickness of gate (i.e. diameter of hinge) should be between 40mm and 70mm.
Front part of gate operator
Weld the straight plate to the gate bracket, make sure E=85mm.
Mark a vertical line around 635mm from the center of hinge. Fig.9
If the gate brackets shipped do not fit your gate because of the dimensions of your gate, you
may have to fabricate brackets for your application or notch a column in order to obtain the
necessary set back.
Fig.8
Fig.9
Mount the rear part of the gate operator on the post bracket using the pin supplied, secure
the pin using the circlip. Fig.10
Install the gate bracket on to the front part of gate operator using the lock nut. See Fig.11
S
S=635mm
Top view
Center of hinge
Gate
Pad
(
not supply
)
S=635mm
2R
E
S
Top view
Center of hinge
Gate
E
Gate bracket
E
Weld the straight
plate to the bracket.
E=85mm