Summary of Contents for SL 2000 DC2

Page 1: ...wered and 12V Low Voltage Installation and Set Up Instructions Unit 27 49 Corporate Boulevard Bayswater Vic 3153 Phone 1800 111 930 Email info gforceautogates com au Web www gforceautogates com au 201...

Page 2: ...e the gate can close without hitting any obstructions or suitable safety accessories are also installed This equipment is designed for use as a Sliding Gate Opening Device only Do not attempt to use f...

Page 3: ...cover Solar Regulator Only installed in solar powered gate motors Drive Gear Limit Switch Spring Circuit Board Manual release mechanism Limit Switch Assembly Remote Receiver Battery Motor Gate motor...

Page 4: ...ush Button Trigger Terminals Connect wires to OSC and COM PE Beam Terminals Connect wires to PEB and COM Power Out Connection Terminals V positive terminal 0V Negative terminal Motor Force Trim Pot PE...

Page 5: ...direction until you can freely move the motor drive gear and or gate freely by hand Automatic Mode Insert the key in the keyhole and turn the key in the Open direction as shown by the arrow on the co...

Page 6: ...rd should now be powered and great care should be taken to avoid shorting out or otherwise damaging the circuit board Green and Red gate direction LED s will flash when power is connected Activate the...

Page 7: ...locate the M1 Motor terminals on the circuit board Swap the red and black motor wires connected to M1 Motor terminals on the circuit board The red wire should be connected to the terminal that had th...

Page 8: ...he drive gear We suggest a gap of 2 3mm between rack and drive gear Temporarily placing a 2 3 mm spacer under the motor feet can help set the required height Remove the spacer when finished To ensure...

Page 9: ...tions when the gate motor is operating the limit switch brackets should push against the limit switch spring to click the limit switch off an audible sound can be heard when the switching occurs Put t...

Page 10: ...orque force to fully open and close the gate However the more torque the motor has the less obstruction sensitivity there is and therefore the gate may hit an obstruc tion more forcefully Usually the...

Page 11: ...Once time is set flick DIP switch 1 back to OFF To start the Auto Close function flick DIP switch 8 to ON and leave it on To disable the Auto Close flick DIP switch 8 back to OFF To adjust the Auto C...

Page 12: ...Cable RED active WHITE neutral Terminal Block Solar Panel Wires RED wire to RED Positive wire BLACK wire to NEGATIVE wire Weather Proof Enclosure Terminal Block Solar Panel Wires POSITIVE wire to gre...

Page 13: ...ative wire to Black battery terminal Terminal Block 12 v Low Voltage Transformer Wires 1 5mm Twin Active Low Voltage Cable Weather Proof Enclosure If the 12 v low voltage transformer wires need to be...

Page 14: ...ranted including but not limited to damages for lost services cost of substitute services lost profits expenses arising out of third party claims or personal injury G Force s maximum liability under a...

Page 15: ...cables are not frayed at the ends 5 Ensure Receiver is firmly mounted 6 Tighten all mounting and attachment bolts 7 Check screws on Push Button covers are intact and tight 8 If Photocells Sensors are...

Reviews: