background image

Ditec NeoS / NeoS+

Sliding Gates

(Original instructions)

www.entrematic.com

IP2160EN

Technical Manual

Summary of Contents for Ditec NES1000EHP

Page 1: ...Ditec NeoS NeoS Sliding Gates Original instructions www entrematic com IP2160EN Technical Manual ...

Page 2: ... 8 Electrical connections 43 8 1 Installation of internal photocell 44 9 Routine maintenance plan 44 Operating instructions 45 i This symbol indicates instructions or notes regarding safety to which special atten tion must be paid This symbol indicates useful information for the correct functioning of the product All the rights concerning this material are the exclusive property of Entrematic Grou...

Page 3: ...y edges emergency stops etc must be installed taking into account applicable laws and directives Good Working Methods installation premises system operating logic and the forces developed by the motorised door or gate The safety devices must protect against crushing cutting trapping and general danger areas of the motorised door or gate Display the signs required by law to identify hazardous areas...

Page 4: ... are properly supervised or have been instructed in the safe use of the device and the relative hazards Children must be supervised to make sure they do not play with the device nor play remain in the sphere of action of the motorised door or gate Keep remote controls and or any other command devices out of the reach of children to avoid any accidental activation of the motorised door or gate In t...

Page 5: ...es a door or gate has the same obligations as the manufacturer of machinery and as such must prepare the technical data sheet which must contain the documents indicated in Annex V of the Machinery Directive The technical data sheet must be kept and placed at the disposal of competent national authori ties for at least ten years from the date of manufacture of the motorised door draw up the EC Decl...

Page 6: ... 1 0 25 m s 0 1 0 25 m s 0 1 0 25 m s Max stroke 12 m 12 m 12 m Max wing weight 400 kg 400 kg 400 kg Service class 4 INTENSE 4 INTENSE 4 INTENSE Intermittence S2 30 min S3 50 S2 30 min S3 50 S2 30 min S3 50 Ambient temperature 20 C 55 C 20 C 55 C 20 C 55 C Degree of protection IP24 IP24 IP24 Control panel CS12E CS12M CS12E Ditec NES600EH Ditec NES600EHP Ditec NES600EHJ Power supply 230 V 50 60Hz 2...

Page 7: ...ge operating conditions and are therefore not necessarily applicable to specific conditions of use Each automatic entrance has variable elements such as friction balancing and environmental factors all of which may substantially alter the performance characteristics of the automatic entrance or curtail its working life or parts thereof including the automatic devices themselves The installer should...

Page 8: ...y selector switch Keypad Wireless keypad 5 LIN2 XEL2 LAB4 Photocells IP55 photocells 6 SOFA SOFB GOPAV Safety edge Radio system for safety edges 7 LAB9 Magnetic loop detector for passage control A Connect the power supply to a type approved omnipolar switch with a contact opening distance of at least 3 mm not supplied The connections to the mains and low voltage wires 230V must be made on an indep...

Page 9: ... 1000 90 210 NES 300 400 220 NES 600 1000 170 NES 300 400 180 NES 600 1000 40 6 Main components Ref Code Description 8 Motor 9 Control panel 10 Diagnostic circuit 11 Key release 12 Pinion 13 Battery kit 14 Cable inlet 15 Power supply terminal 8 11 10 9 8 13 9 15 14 12 ...

Page 10: ... of the wing The opening and closing stops must be fitted If the gate has slits make sure they are covered to prevent shearing points or install active safety edges on the columns Safety device should be installed at the end of the wing to reduce the collision force NB make sure that the gate can not exit the sliding guides and fall 7 Installation The given operating and performance features can on...

Page 11: ...t using a hammer to ensure correct anchorage to the concrete Make a concrete base with the anchor ties and base plate embedded which must be level and clean and of the size indicated in the figure i NB if the concrete base has already been made base plate 2 can be fixed using M8 plugs not supplied OPENING 160 X 25 70 min 40 Ø80 90 300 335 1 CROSSCRN2 CROSSCRI X 40 NES100CKT M12 low type OPENING 160 ...

Page 12: ...talongtheslotsofthegearmotorbaseandverticallywith four levelling screws A NB during the vertical adjustment keep the gearmotor slightly raised from the base plate so that the rack can be fixed and subsequent adjustments are possible After adjusting fix the gearmotor using screws B 7 3 Gearmotor installation WARNING The gearmotor must be suitably raised from the ground to avoid flooding X 105 15 10 5 ...

Page 13: ...er to align the rods correctly use a scrap piece of rack and rest it underneath the junction point as shown in the figure detail Once fixed vertically adjust the gearmotor to give a play of about 2 to 3 mm between the pinion and the rack Secure the gearmotor Slightly lubricate the rack and pinion after assembly Manually check that the gate slides evenly and without friction 7 4 Rack installation 2 3...

Page 14: ...tor For the installation of the limit switch kit refer to the Nes100FCM manual Manually place the wing in the open position and fix limit switch brackets A and B on rack C Repeat this operation with the wing in the closed position After a few manoeuvres adjust the position of limit switch brackets A and B so that the gate stops about 20 mm before reaching the opening and closing mechanical stops i ...

Page 15: ...NB Install the chain drive kit before securing the gearmotor to the base plate 7 7 Chain drive kit installation i Move the wing into the open position by hand and fix brackets D on the wing as illustrated in the diagram Connect chain E which was previously assembled on the gearmotor to tie rod F and fix it to bracket D Fix bracket D on the opposite side of the gate Connect chain E to tie rod F and fi...

Page 16: ...orrect when the gate is fully open and closed Secure the chain with nuts G Tighten the chain E with the tie rods F Slightly lubricate the chain E and the pinions after assembly WARNING when the chain traction kit is fitted the gearmotor drive direction is inverted Right hand opening Left hand opening ...

Page 17: ...nections to the mains power supply and any other low voltage wires 230V must be made on an independent channel separated from the connections to the command and safety devices SELV Safety Extra Low Voltage The channel must penetrate the automation through the holes on the base plate by a few cen timetres Make sure there are no sharp edges that may damage the power supply cable Make sure the mains ...

Page 18: ...otor Make sure the limit switches are working correctly Check the power adjustment Check that all control and safety functions are working correctly NB For spare parts see the spares price list 9 Routine maintenance plan i Additional photocells can be installed inside the gearmotor casing of Ditec NEOS to protect both opening and closing movements by using the LIN2 photocell Fit a receiver RX or a...

Page 19: ...easonable use Do not use the sliding gate if it needs repairing or adjusting Disconnect the power supply when carrying out cleaning or maintenance tasks The motorised gate may be used by children over the age of 8 and by people with reduced physical sensorial or mental abili ties or lack of experience or knowledge as long as they are properly supervised or have been instructed in the safe use of t...

Page 20: ...0EH NES600EHP NES600EHJ NES1000EHP NES1000EHPJ Power 230V 50 60 Hz 230V 50 60 Hz 120V 50 60 Hz 230V 50 60 Hz 120V 50 60 Hz Power 1 5 A 300W 1 5 A 300W 3 A 300W 2 A 400W 4 A 400W Fuse F2 A F4 A F2 5 A F6 3 A Ambient temperature 20 C 55 C Degree of protection IP24 Control panel CS12E CS12M CS12E CS12M CS12M Acoustic pressure 70 dB A Certifications Certifications of third parties supplied by accredited...

Page 21: ...hotocells are clean Do not use alkaline based prod ucts Do not use high pressure water jets The automatic system function selector switches and photocells could get damaged Do not use polishing detergents Do not rub with abra sive products as they could cause damage Reconnect the power supply then check the limit switches if fitted are working correctly the power adjustments are correct this operat...

Page 22: ...lamp has blown Replace it The wires are damaged or detached or have short circuited Contact Technical Service The gate open indicator light doesn t work The lamp has blown Replace it The wires are damaged or detached or have short circuited Contact Technical Service If the problem persists contact Ditec ENTREMATIC Technical Service explaining the type of alarm indicated by the LEDs G G G R R R Y Y...

Page 23: ...ematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www entrematic com Only use original spare parts when repairing or replacing products The installer must supply all information on the automatic manual and emergency operation of the motorised door and must provide the user with the operating instructions The installer must prepare and keep a maintenance record showing all the routine and...