e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
6 - 82
[CC52] Skew adjustment motor (M1) abnormality
[CC60] Punch motor abnormality
* The [CC52] error will be displays when the [ED10] error occurs three times in succession or
during the initial operation.
MJ-1101 (When MJ-6101 is installed)
Is there any paper remaining on the transport path?
YES Remove the paper.
NO
Rotate the skew adjustment motor (M1). Does it rotate smoothly?
NO Fix
the
mechanism.
YES
Are the skew home position sensor (S2) and its wiring correct?
NO
Replace the sensor. Correct the wiring.
YES
Is the wiring between the hole punch control PC board (HP) and skew adjustment motor (M1)
correct?
NO Correct
the
wiring.
YES
1. Replace the skew adjustment motor (M1).
2. Replace the hole punch control PC board (HP).
MJ-1030 (when MJ-6004 is installed)
Are the punch home position sensor (PI63) and punch motor clock sensor (PI62) working
normally?
NO
Replace the sensors.
YES
Is the wiring between the sensors and finisher controller PC board correct?
NO
Correct the wiring.
YES
Is the punching mechanism normal?
NO
Fix the mechanism.
YES
1. Replace the punch motor (M61).
2. Replace the punch controller PC board.
3. Replace the finisher controller PC board.