[EAF0]
Stack return jam
MJ-1022
Is there any paper remaining on the transport path in the finisher or equipment?
#
YES
Remove the paper.
NO
Is the connector J10 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and returning roller home position
sensor (S3) open circuited?
#
YES
Connect the connector securely. Replace the harness.
NO
Is the returning roller home position sensor working properly?
l
l
#
NO
1) Connect the connector of the returning roller home position sensor
securely.
2) Replace the returning roller home position sensor.
YES
Replace the finisher controller PC board.