e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
June 2004 © TOSHIBA TEC
5 - 26
[E450]
LCF side cover opened during printing
Is the LCF side cover open?
#
YES
Remove the paper if there is any, then close the cover.
NO
Is the LCF side cover opening/closing switch working?
(Perform the input check in the test mode: 03-[FAX]OFF/[5]/[D])
l
l
l
l
l
l
l
l
l
l
l
l
#
NO
1) Check if the connector of the LCF side cover opening/closing switch
is disconnected.
2) Check if either of the connectors CN100 or CN106 on the LCF board
is disconnected.
3) Check if the connector CN310 on the LGC board is disconnected.
4) Check if the connector pins are disconnected and the harnesses are
open circuited.
5) Check if the conductor patterns on the LCF board and LGC board are
short circuited or open circuited.
6) Replace the LCF side cover opening/closing switch.
7) Replace the LCF board.
8) Replace the LGC board.
YES
1) Replace the LCF board.
2) Replace the LGC board.
[E480]
Bridge unit opened during printing
Is the bridge unit open?
#
YES
Remove the paper if there is any, then close the unit.
NO
Is the bridge unit opening/closing switch working?
(Perform the input check in the test mode: 03-[FAX]ON/[3]/[F])
l
l
l
l
l
l
l
l
l
#
NO
1) Check if the connector of the bridge unit opening/closing switch is
disconnected.
2) Check if the connector CN306 on the LGC board is disconnected.
3) Check if the connector pins are disconnected and the harnesses are
open circuited.
4) Check if the conductor pattern on the LGC board is short circuited or
open circuited.
5) Replace the bridge unit opening/closing switch.
6) Replace the LGC board.
YES
Replace the LGC board.
Содержание e-STUDIO200L
Страница 6: ......
Страница 12: ......
Страница 36: ...e STUDIO200L 202L 230 232 280 282 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES June 2004 TOSHIBA TEC 1 24 ...
Страница 296: ...e STUDIO200L 202L 230 232 280 282 ERROR CODE AND SELF DIAGNOSTIC MODE June 2004 TOSHIBA TEC 2 260 ...
Страница 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Страница 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Страница 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Страница 700: ...e STUDIO200L 202L 230 232 280 282 DATA CLONING with USB STORAGE DEVICE e STUDIO202L 232 282 June 2004 TOSHIBA TEC 9 22 ...
Страница 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Страница 707: ......
Страница 708: ......