e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
June 2004 © TOSHIBA TEC
3 - 82
3.11.6
Adjustment of Copy Ratio
Note:
Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the RADF. Also, the RADF position and height shall be adjusted properly.
[A]
Checking
Check the image using the chart (original) with vertical and horizontal lines in the following procedure.
(1)
Place the chart provided as an original with its face up on the original tray of the RADF.
(2)
Press the [START] button.
(3)
Superimpose the chart on the copy and check the image dimension “I”.
[B]
Adjustment
(1)
Turn the power ON while pressing [0] and [5] simultaneously.
(2)
Key in [357] and then press the [START] button.
•
If the copy image dimension “I” is larger than the chart dimension, enter a value smaller than
the current one.
•
If the copy image dimension “I” is smaller than the chart dimension, enter a value larger than
the current one.
Fig.3-106
(3)
Press the [ENTER] button.
I
05/11
Содержание e-STUDIO200L
Страница 6: ......
Страница 12: ......
Страница 36: ...e STUDIO200L 202L 230 232 280 282 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES June 2004 TOSHIBA TEC 1 24 ...
Страница 296: ...e STUDIO200L 202L 230 232 280 282 ERROR CODE AND SELF DIAGNOSTIC MODE June 2004 TOSHIBA TEC 2 260 ...
Страница 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Страница 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Страница 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Страница 700: ...e STUDIO200L 202L 230 232 280 282 DATA CLONING with USB STORAGE DEVICE e STUDIO202L 232 282 June 2004 TOSHIBA TEC 9 22 ...
Страница 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Страница 707: ......
Страница 708: ......