e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
June 2004 © TOSHIBA TEC
2 - 120
707
Mainte-
nance
Remote-controlled service
HTTP initially-registered
server
URL setting
ALL
https://
device.
mfp-
support.
com:443/
device/
firstregist.
ashx
SYS
Maximum 256 Bytes
11
710
Mainte-
nance
(Remote)
Short time interval setting
of recovery from Emer-
gency Mode
ALL
24
<1-48>
SYS
Sets the time interval to
recover from the Emer-
gency Mode to the Nor-
mal Mode.
(Unit: Hour)
1
711
Mainte-
nance
(Remote)
Short time interval setting
of Emergency Mode
ALL
60
<30-360>
SYS
Unit: Minute
1
715
Mainte-
nance
Remote-controlled service
periodical polling timing
(Hour/Hour/Minute/Minute)
ALL
1230
SYS
0 (0:00) to 2359 (23:59)
1
716
Mainte-
nance
Remote-controlled service
Writing data of self-diag-
nostic code
ALL
0
<0-1>
SYS
0: Prohibited
1: Accepted
1
717
Mainte-
nance
Remote-controlled service
response waiting time
(Timeout)
ALL
3
<1-30>
SYS
Unit: Minute
1
718
Mainte-
nance
Remote-controlled service
initial registration
ALL
0
<0-2>
SYS
0: OFF
1: Start
2: Only certification is
scanned
1
719
Mainte-
nance
Remote-controlled service
tentative password
ALL
-
SYS
Maximum 10 letters
11
720
Mainte-
nance
Status of remote-con-
trolled service initial regis-
tration
(Display only)
ALL
0
<0-1>
SYS
0: Not registered
1: Registered
2
721
Mainte-
nance
Service center call function
ALL
2
<0-2>
SYS
0: OFF
1: Notifies all service
calls
2: Notifies all but
paper jams
1
723
Mainte-
nance
Service center call
HTTP server URL setting
ALL
-
SYS
Maximum 256 letters
11
726
Mainte-
nance
HTTP proxy setting
ALL
1
<0-1>
SYS
0: Valid
1: Invalid
1
727
Mainte-
nance
HTTP proxy IP address
setting
ALL
-
SYS
000.000.000.000-
255.255.255.255
(Default value
000.000.000.000)
11
728
Mainte-
nance
HTTP proxy port number
setting
ALL
0
<0-
65535>
SYS
1
729
Mainte-
nance
HTTP proxy ID setting
ALL
-
SYS
Maximum 30 letters
11
730
Mainte-
nance
HTTP proxy password set-
ting
ALL
-
SYS
Maximum 30 letters
11
731
Mainte-
nance
HTTP proxy panel display
ALL
1
<0-1>
SYS
0: Valid
1: Invalid
1
Setting mode (08) <e-STUDIO200L/230/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
04/09
Содержание e-STUDIO200L
Страница 6: ......
Страница 12: ......
Страница 36: ...e STUDIO200L 202L 230 232 280 282 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES June 2004 TOSHIBA TEC 1 24 ...
Страница 296: ...e STUDIO200L 202L 230 232 280 282 ERROR CODE AND SELF DIAGNOSTIC MODE June 2004 TOSHIBA TEC 2 260 ...
Страница 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Страница 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Страница 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Страница 700: ...e STUDIO200L 202L 230 232 280 282 DATA CLONING with USB STORAGE DEVICE e STUDIO202L 232 282 June 2004 TOSHIBA TEC 9 22 ...
Страница 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Страница 707: ......
Страница 708: ......