June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 47
3
[B]
Adjustment of the magnification ratio of the lens
Notes:
•
Perform this adjustment only when the lens unit is taken off or replaced.
•
Make sure that the primary scanning reproduction ratio (printer section) is correct before this
adjustment.
(1)
Place a ruler on the original glass (in the primary scanning direction) and make a copy on A4/LT-
sized paper at 100% reproduction ratio.
(3)
If each mark on the rulers differs, perform the adjustment with the following procedures.
<Procedure>
(2)
Compare the copied ruler with the actual
ruler.
Fig.3-37
(1)
Take off the original glass and lens cover.
(2)
Loosen 2 screws fixing the lens unit.
Fig.3-38
Feeding Direction
Actual ruler
Copied ruler
Lens unit
Screw
Содержание e-STUDIO200L
Страница 6: ......
Страница 12: ......
Страница 36: ...e STUDIO200L 202L 230 232 280 282 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES June 2004 TOSHIBA TEC 1 24 ...
Страница 296: ...e STUDIO200L 202L 230 232 280 282 ERROR CODE AND SELF DIAGNOSTIC MODE June 2004 TOSHIBA TEC 2 260 ...
Страница 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Страница 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Страница 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Страница 700: ...e STUDIO200L 202L 230 232 280 282 DATA CLONING with USB STORAGE DEVICE e STUDIO202L 232 282 June 2004 TOSHIBA TEC 9 22 ...
Страница 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Страница 707: ......
Страница 708: ......