e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
June 2004 © TOSHIBA TEC
3 - 36
[B]
Connection for developer bias adjustment
Fig.3-23
[C]
Connection for main charger adjustment
Fig.3-24
Front cover opening/closing switch
Ground to the
machine frame
(green cable)
(-) terminal:
Connect with the white cable
(+) terminal:
Connect with the black cable
Front cover opening/closing switch
Ground to the
machine frame
(green cable)
(-) terminal:
Connect with the white cable
(+) terminal:
Connect with the
red cable (thick line)
Содержание e-STUDIO200L