3.15 Adjustment of Dogleg
Dogleg is the name given to an image which is deformed approx. 48 mm of the trailing edge of the out-
put paper.
Since adjustment has usually been performed when the equipment was manufactured, dogleg image
should not occur. However, if the following dogleg image A or B does happen to occur, the following
adjustment must be performed. An original with a line parallel to the feeding direction is used for the
adjustment.
Fig.3-138
Fig.3-139
Fig.3-140
Normal Image
Feeding
Direction
Feeding
Direction
Dogleg Image A
Approx. 48 mm of
the trailing edge
Dogleg Image B
Feeding
Direction
Approx. 48 mm of
the trailing edge